Philips Sopho 2000 IPS User Manual page 660

Hide thumbs Also See for Sopho 2000 IPS:
Table of Contents

Advertisement

F
CMD102
On the AP00 card, set SW1 switch as shown
below.
SW 1
4
3
2
1
ON
Clear the billing memory.
NOTE:
Before executing CMD102, be sure
to save/print out all of the stored call
records.
CMD102 deletes all of the stored
records.
On the AP00 card, set the SW1 switch as
shown below.
SW 1
4
3
2
1
ON
CMD000
The buffering method when the number of the
stored SMDR information has reached the pre-
determined value.
CM44
The external alarm driver function for the
SMDR buffer overflow.
G
DESCRIPTION
: POSITION TO BE SET
AP OFF LINE
: POSITION TO BE SET
STATION MESSAGE DETAIL RECORDING (SMDR)
SW1-4 should be set as follows;
ON : The AP No. is 04-15
OFF: The AP No. is 20-31
(1)
0000
(2)
CCC
SW1-4 should be set as follows;
ON : The AP No. is 04-15
OFF: The AP No. is 20-31
(1)
41
(2)
0 : No new data is stored
1 : New data is stored by deleting the old-
est data
(1)
XX Y
XX: 00-31: DK Card No. assigned by
CM10/CM14 (E800-E831)
Y : 0-3: Circuit No.
(2)
3001: When CMD001>80/100/120/140 is
set to "4"
3002: When CMD001>80/100/120/140 is
set to "5"
– 642 –
PROGRAMMING
DATA
NWA-008845-001 Rev.5.0
32ch1010.fm
JULY/01/2006