Mr-J2S-Series Power Factor Improving Dc Reactor (400 V Class) - Mitsubishi Electric MELSERVO-J2S Series Transition Handbook

Servo amplifiers & motors
Hide thumbs Also See for MELSERVO-J2S Series:
Table of Contents

Advertisement

Part 9: Review on Replacement of Optional Peripheral Equipment

7.4 MR-J2S-Series Power Factor Improving DC Reactor (400 V class)

The input power factor is improved to about 95%.
Power factor
improving
Servo amplifier
DC reactor
MR-J2S-11K_4
FR-BEL-H15K
MR-J2S-15K_4
FR-BEL-H22K
MR-J2S-22K_4
FR-BEL-H30K
Terminal cover
SERVO
AMPLIFIER
MR-J2S-30K_4
MR-J2S-37K_4
MR-J2S-45K_4
MR-J2S-55K_4
(Note 1) Terminal cover
Screw size G
Name
plate
Lower than A
5 m or lower
FR-BEL
(Note 2)
Note 1. Since the terminal cover is supplied, attach it after connecting a wire.
2. When using a power factor improving DC reactor, remove the short-circuit bar between
P
and P.
1
Dimensions [mm]
B
C
A
D
170
93
160
2.3
185
119
171
2.6
185
119
189
2.6
+1.5
X
-1.5
D or less
Power factor
improving
DC reactor
MR-DCL30K-4
135
MR-DCL37K-4
135
MR-DCL45K-4
135
MR-DCL55K-4
135
Notch
Lower than B
Servo amplifier
P
P
1
E
F
L
G
155
6
14
M6
165
7
15
M6
165
7
15
M6
Terminal block (M3.5 screw)
For thermal protector
P1
Approx. W1
Mounting hole
for M8
W or less
Dimensions [mm]
W
D
H
W1
X
205
200
75
175
225
200
80
197
240
200
80
212
260
215
80
232
9 - 40
Mounting leg portion
Mounting
Mass
screw
[kg]
H
Size
56
M5
3.7
70
M6
5.0
70
M6
6.7
Terminal screw
P2
Mounting
Mass
screw
[kg]
Size
M8
6.5
M8
7
M8
7.5
M8
9.5
Electric
wire
[mm
2
]
8(AWG8)
22(AWG4)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMelservo-j2m seriesMelservo-j4 seriesMr-j2s-10aMr-j2s-20aMr-j2s-40a ... Show all