Mitsubishi Electric MELSERVO-J2S Series Transition Handbook page 46

Servo amplifiers & motors
Hide thumbs Also See for MELSERVO-J2S Series:
Table of Contents

Advertisement

Part 2: Review on Replacement of MR-J2S-_A_ with MR-J4-_A_
(2) Position control mode
Parameter
number
PA01
Operation mode
PA06
Electronic gear numerator
(Commanded pulse
multiplication numerator)
PA07
Electronic gear denominator
(Commanded pulse
multiplication denominator)
PA13
Command pulse input form
Note. The example value shown is for when the electronic gear ratio of an existing servo amplifier is set as "8/1".
(3) Speed control mode
Parameter
number
PA01
Operation mode
PC12
Analog speed command -
Maximum speed
(4) Torque control mode
Parameter
number
PA01
Operation mode
PC12
Analog speed limit -
Maximum speed
PC13
Analog torque command -
Maximum output
Name
Initial
value
1 0 0 0h
1
1
0 1 0 0h
Name
Initial
value
1 0 0 0h
0
Name
Initial
value
1 0 0 0h
0
100.0
Setting
value
_ _ _ 0h
Select the servo amplifier control mode.
Select the position control mode.
256
When using an electronic gear, it is necessary to change the
setting value.
(Note)
For simultaneous replacement, set a value by calculating as
follows:
1
(Note)
Replacement servo motor
CMX
Encoder resolution
=
CDV
Servo motor for MR-J2S
Encoder resolution
When a geared servo motor is replaced, the actual reduction
ratio may differ before and after the replacement. If the ratio
differs after the replacement, set the values considering the
actual reduction ratio.
_ x _ _h
Command input pulse train filter selection
Selecting the proper filter enables noise immunity enhancement.
Make sure to select a filter so as not to cause a position
mismatch. For details, refer to "MR-J4-_A_ [Pr. PA13]" in
Section 3.6.3.
In addition, it is necessary to adjust the command pulse logic to
the positioning module. An incorrect logic setting causes the
servo motor to not rotate. Make sure to configure the settings.
Refer to "3.7 Important Points for Replacement (Command
Pulse Logic Settings)".
Setting
value
_ _ _ 2h
Select the servo amplifier control mode.
Select the speed control mode.
3000
Analog speed command - Maximum speed
The setting value at left is for when the HC-SFS53 motor is
replaced with the HG-SR52 motor.
Setting
value
_ _ _ 4h
Select the servo amplifier control mode.
Select the torque control mode.
3000
Analog speed limit - Maximum speed
The setting value at left is for when the HC-SFS53 motor is
replaced with the HG-SR52 motor.
100.0
Analog torque command - Maximum output
Set the same value as for the MR-J2S-_A_ servo amplifier.
2 - 15
Description
Former CMX
4194304
=
Former CDV
131072
Description
Description
1
256
=
8
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMelservo-j2m seriesMelservo-j4 seriesMr-j2s-10aMr-j2s-20aMr-j2s-40a ... Show all

Table of Contents