Mitsubishi Electric MELSERVO-J2S Series Transition Handbook page 185

Servo amplifiers & motors
Hide thumbs Also See for MELSERVO-J2S Series:
Table of Contents

Advertisement

Part 5: Review on Replacement of MR-J2S-30 kW or Higher Capacity Models with MR-J4-DU_
(c) Comparison of signals
MR-J2S-_B_
Connector pin assignment
CON2
CN3
CN4
Note 1. The factory setting for MR-J4-_B_ is EM2.
2. Set with [Pr. PD07] to [Pr. PD09] for use.
3. Signals unique to MR-J4-_B_ are in parentheses.
Abbreviation
Connector pin No.
(Note 3)
SG
CON2-1
(DOCOM)
EM1
CON2-2
(EM2)
CON2-3
MBR
CON2-4
DB
CON2-15
VDD
COM
CON2-18
(DICOM)
CN3-6
LA
CN3-16
LAR
CN3-7
LB
CN3-17
LBR
CN3-8
LZ
CN3-18
LZR
CN4-1
MO1
CN4-2
MO2
CN4-4
LG
Plate
SD
5 - 24
MR-J4-_B_
Connector pin No.
Connector pin assignment
CN3-3
CN3-20 (Note 1)
CN3-13
(Note 2)
CN3-5
CN3-10
DI1
CN3-6
MO1
CN3-16
CN3-7
CN3-17
CN3-8
CN3-18
DICOM
CN3-4
CN3-14
CN3-1
CN3-11
Plate
CN3
1
11
2
12
LG
LG
DI2
3
13
4
14
MBR
DOCOM
MO2
5
15
6
16
ALM
DICOM
LA
LAR
7
17
8
18
LB
LBR
LZ
LZR
9
19
10
20
INP
DI3
EM2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMelservo-j2m seriesMelservo-j4 seriesMr-j2s-10aMr-j2s-20aMr-j2s-40a ... Show all

Table of Contents