[Appendix 2] Introduction to Renewal Tool
(1) Common items
Item
Built-in (0.1 kW to 7 kW)
Dynamic brakes
External (11 kW to 55 kW)
Regenerative
Built-in (0.2 kW to 7 kW)
resistor
External (11 kW to 22 kW)
24 V DC ±15%
control circuit power
1-phase 100 V AC to 120 V AC
supply
1-phase 200 V AC to 230 V AC
1-phase 380 V AC to 480 V AC
1-phase 100 V AC to 120 V AC
1-phase/3-phase 200 V AC to 230 V
Main circuit power
AC
supply
1-phase/3-phase 380 V AC to 480 V
AC
Interface
24 V DC power
Built-in
supply
For 200 V: 0.1 kW to 1 kW: Plug-in
type connector
Control circuit
2 kW or more: Terminal block
power/regenerative
For 400 V:
resistor terminal
0.6 kW to 2 kW: Plug-in type
connection method
connector
3.5 kW or more: Terminal block
Main circuit power
For 200 V: Terminal block
supply
For 400 V: 0.6 kW to 2 kW: Plug-in
terminal connection
type connector
method
3.5 kW or more: Terminal block
Auto
Real-time auto
tuning
tuning: 15 steps
Advanced vibration
suppression control
Unprovided
Adaptive
Provided (Ⅰ)
filter
Notch filter
Provided (2 pcs.)
Tough drive function Unprovided
Drive recorder
Unprovided
function
Restart after
instantaneous
Supported
power failure
Natural cooling (0.1 kW to 1 kW)
Cooling method
Force cooling (2 kW to 22 kW)
Heatsink
MR-JACN_ (11 kW to 22 kW)
Outside mounting
MR-ACN_ (30 kW to 55 kW)
attachment
○: Compatible; △: Limited functions or compatible with certain conditions; ×: Incompatible
Refer to Appendix page 2-10 for important points to note.
MR-J2S series
Built-in (0.1 kW to 7 kW)
External (11 kW to 55 kW)
* Coasting distance is different.
Built-in (0.2 kW to 7 kW)
External (11 kW to 22 kW)
1-phase 100 V AC to 120 V AC
1-phase 200 V AC to 240 V AC
1-phase 380 V AC to 480 V AC
1-phase 100 V AC to 120 V AC
1-phase/3-phase 200 V AC to 240 V
AC
1-phase/3-phase 380 V AC to 480 V
AC
External supply required
For 200 V: 0.1 kW to 3.5 kW: Plug-in
type connector
5 kW or more: Terminal block
For 400 V:
0.6 kW to 3.5 kW: Plug-in type
connector
5 kW or more: Terminal block
For 200 V: 0.1 kW to 3.5 kW: Plug-in
type connector
5 kW or more: Terminal block
For 400 V: 0.6 kW to 3.5 kW: Plug-in
type connector
5 kW or more: Terminal block
Real-time auto
tuning: 40 steps
One-touch tuning
Provided
Provided (II: with improved function)
Provided (5 pcs.)
Provided
Provided
None
Natural cooling (0.1 kW to 0.6 kW)
Force cooling (0.7 kW to 22 kW)
MR-J4ACN_ (11 kW, 15 kW)
MR-J3ACN (22 kW)
30 kW to 55 kW: Unprovided
Appendix 2-5
*When the renewal tool is used.
When the
renewal tool is
MR-J4 series
External supply
required
For 200 V:
With terminal
block
conversion
For 200 V:
With terminal
block
conversion
(other than of 5
kW)
Compatibility
Remarks
(*)
used
(Note 2)
(Note 3)
(Note 18)
×
(Note 4)
(Note 19)
(Note 19)
×
(Note 5)
(Note 6)
×
(Note 21)