Mitsubishi Electric MELSERVO-J2S Series Transition Handbook page 603

Servo amplifiers & motors
Hide thumbs Also See for MELSERVO-J2S Series:
Table of Contents

Advertisement

[Appendix 2] Introduction to Renewal Tool
5. RENEWAL TOOL CONNECTION DIAGRAM
These diagrams are the connection diagrams for wiring the servo amplifier and servo motor when using the
renewal tool.
* Since a terminal block is not included with the renewal tool (mounting attachment) for 400 V, refer to MR-J4
Servo Amplifier Instruction Manual for the detailed connection.
5.1 SC-J2SJ4(CP)KT02K to 3K
(1) Primary replacement (when replacing the servo amplifier only)
For 3-phase 200 V connection
3- phase
200 to 230VAC
The amplifier capacity is 0.4 kW or less
1-phase 100 V connection
1-phase
100 to 120VAC
No.
Product name
① Servo amplifier
② Servo motor
③ Renewal kit
④ Encoder conversion cable
⑤ Control signal conversion cable
⑥ Monitor conversion cable
⑦ 24 V DC power supply connection cable
*1: Manufactured by Mitsubishi Electric.
Note 1. When using the regenerative option, make sure to remove the wiring or the short-circuit bar across P (+) and D, connect with
the wiring between the renewal kit and the servo amplifier, and mount the regenerative option between P and C.
When using a built-in regenerative resistor, make sure to connect the wiring or the short-circuit bar across P (+) and D. For
SC-J2S(CP)J4KT3K, insulate the wiring between the renewal kit and the servo amplifier. Ensure the connection destinations
are correct. The servo amplifier may malfunction if the connection destinations are incorrect.
2. The N terminal of TE2 is limited to SC-J2S(CP)J4KT1K and 3K. There is no D terminal wiring for SC-J2S(CP)J4KT3K.
3. Required only when the internal power supply (24 V DC) for the I/F is used in the existing MR-J2S servo amplifier. Not
included with the renewal tool. Note that a separate 24 V DC power supply (current capacity: 80 mA or more) is required when
replacing.
When connecting the 24 V DC power supply, use the "24 V DC power supply connection cable (model: SC-J2SJ4CTPWC5M)"
included in the package. (Electric wire colors: Red (+ side); white (- side))
Renewal kit
(SC-J2S(CP)J4KT02 to 3K)
Servo amplifier (MR-J4-_A(1)(-RJ))
(Note 2)
(Note 1)
(Note 2)
Unassigned
1-phase
100VAC
Connection of regenerative option
(for SC-J2S(CP)J4KT02K to 1K)
Regenerative
option
(Note 1)
*1
*1
Make sure to remove the short-circuit bar
Make sure to remove the wiring for the built-in
regenerative resistor.
across P and D.
Connection of the built-in regenerative option
(for SC-J2S(CP)J4KT02K to 1K)
Make sure to connect the short-circuit
Make sure to connect the short-circuit
bar across P and D.
bar across P and D.
Appendix 2-66
Encoder
CN2
conversion cable
Control signal
conversion cable
Monitor conversion
cable
24VDC power supply
Power supply
connection cable
for I/F
(24VDC)
(Note 3)
(for SC-J2S(CP)J4KT3K)
Regenerative
option
Make sure to remove the wiring between P+
and D.
(for SC-J2S(CP)J4KT3K)
(Note 1)
Make sure to insulate the wiring.
MR-J2S
servo motor
Encoder
CN1B
CN1A
Control
signal
CN3
Analog
monitor
(Note 1)
Make sure to remove the
wiring between P+ and D.
Make sure to connect
Make sure to
the wiring between P+
connect the wiring
(Note 1)
and D.
between P+ and D.