[Appendix 2] Introduction to Renewal Tool
5.3 SC-J2S(CP)J4KT7K
(1) Primary replacement (when replacing the servo amplifier only)
For 3-phase 200 V connection
NFB
MC
3-phase
200 to
23 VAC
Note 1. When using the regenerative option, make sure to remove the wiring for the regenerative resistor built in to the servo amplifier,
and mount the regenerative option between P+ and C. Ensure the connection destinations are correct. The servo amplifier
may malfunction if the connection destinations are incorrect.
2. There is no conversion terminal block in the SC-J2S(CP)J4KT7K renewal kit. Directly connect to the MR-J4 servo amplifier.
3. Required only when the internal power supply (24 V DC) for the I/F is used in the existing MR-J2S servo amplifier. Not
included with the renewal tool. Note that a separate 24 V DC power supply (current capacity: 80 mA or more) is required when
replacing.
When connecting the 24 V DC power supply, use the "24 V DC power supply connection cable (model: SC-J2SJ4CTPWC5M)"
included in the package. (Electric wire colors: Red (+ side); white (- side))
Renewal kit
(SC-J2S(CP)J4KT7K)
Servo amplifier (MR-J4-700A(-RJ))
①
U
(Note 2)
L1
V
L2
W
L3
P3
CN2
P4
N-
P+
Built-in
(Note 1)
regenerative
C
resistor
L11
CN1
L21
CN6
Power supply
L
1-phase
100 V AC
(24 V DC)
N
(Note 3)
Connection of regenerative option
(for SC-J2S(CP)J4KT7K)
Regenerative
option
Make sure to remove the wiring for the
built-in regenerative resistor.
Appendix 2-70
③
④
Encoder
CN2
CN2
conversion cable
⑤
Control signal
conversion cable
⑥
Monitor
conversion cable
⑦
24 V DC power supply
+V
connection cable
for I/F
-V
(Note 1)
P+
Built-in
regenerative
C
resistor
servo motor
U
V
W
CN1B
CN1A
Control
signal
CN3
Analog
monitor
No.
Product name
① Servo amplifier
② Servo motor
③ Renewal kit
④ Encoder conversion cable
⑤ Control signal conversion cable
⑥ Monitor conversion cable
⑦ 24 V DC power supply connection cable
*1: Manufactured by Mitsubishi Electric.
MR-J2S
②
M
Encoder
*1
*1