Part 5: Review on Replacement of MR-J2S-30 kW or Higher Capacity Models with MR-J4-DU_
5. OPTIONS AND PERIPHERAL EQUIPMENT
5.1 Comparison Table of Cable Option Combinations
Application
Protection coordination cable
Connector set
Magnetic contactor wiring connector
Digital I/O connector
Terminal connector
Note. Packed with a converter unit
5.1.1 MR-J3CDL05M (0.5 m) Protection Coordination Cable
Note
This is a cable to connect a converter unit and drive unit.
(1) Internal wiring diagram
Cable option combinations
MR-J2S series
MR-J2HBUS_M
MR-J2CNS
MR-HP4CN1
MR-A-TM
When fabricating a protection coordination cable, do wiring correctly. Failure to do
so may result in the servo motor working unexpectedly.
10120-3000PE (Connector)
10320-52F0-008 (Shell kit)
9
19
10
20
7
17
8
18
5
15
Converter unit side
6
16
3
13
4
14
1
11
2
12
Plate
MR-J4 series
MR-J3CDL05M
MR-J2CN1-A
Note
Note
MR-J3CDL05M
PCR-S20FS+ (Connector)
PCR-LS20LA1 (Case)
1
ACD2
11
ACD2*
2
ACD3
12
ACD3*
3
PAL
13
PAL*
4
ACD1
14
ACD1*
5
LG
15
LG
6
GOF
16
GOF*
7
PMC
17
PMC*
8
PSD
18
PSD*
9
LG
19
LG
10
PRD
20
PRD*
Plate
SD
5 - 32
Note
Connector shape will be changed.
Cable must be changed.
Connector shape will be changed.
Cable must be changed.
Prepare a new cable.
Connector shape will be changed.
Cable must be changed.
Drive unit side