[Appendix 2] Introduction to Renewal Tool
5.7 SC-J2SBJ4KT7K
(1) Primary replacement (when replacing the servo amplifier only)
For 3-phase 200 V connection
NFB
3-phase
200 to 230VAC
Note 1. When using the regenerative option, make sure to remove the wiring for the regenerative resistor built in to the servo amplifier,
and mount the regenerative option between P+ and C. Ensure the connection destinations are correct. The servo amplifier
may malfunction if the connection destinations are incorrect.
2. There is no conversion terminal block in the SC-J2SBJ4KT7K renewal kit. Directly connect to the MR-J4 servo amplifier.
3. Required only when the internal power supply (24 V DC) for the I/F is used in the existing MR-J2S-_B servo amplifier.
Not included with the renewal tool. Note that a separate 24 V DC power supply (current capacity: 80 mA or more) is required
when replacing.
When connecting the 24 V DC power supply, use the "24 V DC power supply connection cable (model: SC-J2SJ4CTPWC5M)"
included in the package. (Electric wire colors: Red (+ side); white (- side))
Renewal kit
(SC-J2SBJ4KT7K)
Servo amplifier
(MR-J4-700B-RJ020)
①
MC
(Note 2)
L1
L2
L3
P3
P4
N-
P+
(Note 1)
C
L11
L21
CN3
L
1-phase
N
(Note 3)
Connection of regenerative option
(for SC-J2SBJ4KT7K)
Regenerative
option
Make sure to remove the wiring for the
built-in regenerative resistor.
Appendix 2-78
④
U
V
W
⑤
Encoder
CN2
conversion cable
Built-in
regenerati
SSCNET conversion unit
ve resistor
(ME-J4-T20)
③
CN10A
CN10B
⑥
Control signal
conversion cable
⑦
24VDC power supply
connection cable
+V
Power supply
for I/F
(24 V DC)
-V
(Note 1)
P+
Built-in
regenerati
C
ve resistor
U
V
W
CN2
Controller
or servo
amplifier
Servo
amplifier or
termination
resistor
CN3
Control
signal
Analog
monitor
No.
Product name
① Servo amplifier
② Servo motor
③ SSCNET conversion unit
④ Renewal kit
⑤ Encoder conversion cable
⑥ Control signal conversion cable
⑦ 24 V DC power supply connection cable
*1: Manufactured by Mitsubishi Electric.
MR-J2S
servo motor
②
M
Encoder
*1
*1
*1