Mitsubishi Electric MELSERVO-J2S Series Transition Handbook page 332

Servo amplifiers & motors
Hide thumbs Also See for MELSERVO-J2S Series:
Table of Contents

Advertisement

Part 7: Common Reference Material
MR-J2S-_B_
No.
Name
Machine resonance suppression
61
filter 2
MR-J4-_B_
Type
Target
No.
Type
_ _ XX
PB15
Dec
Hex
_ _ XX
PB16
Hex
_ X_ _
PB16
Hex
Hex: hexadecimal parameter; Dec: decimal parameter
7 - 93
Conversion rule
Target
_ _ 00 will be changed to 4500.
_ _ 01 will be changed to 4500.
_ _ 02 will be changed to 2250.
_ _ 03 will be changed to 1500.
_ _ 04 will be changed to 1125.
_ _ 05 will be changed to 900.
_ _ 06 will be changed to 750.
_ _ 07 will be changed to 643.
_ _ 08 will be changed to 563.
_ _ 09 will be changed to 500.
_ _ 0A will be changed to 450.
_ _ 0B will be changed to 409.
_ _ 0C will be changed to 375.
_ _ 0D will be changed to 346.
_ _ 0E will be changed to 321.
_ _ 0F will be changed to 300.
-
_ _ 10 will be changed to 281.
_ _ 11 will be changed to 265.
_ _ 12 will be changed to 250.
_ _ 13 will be changed to 237.
_ _ 14 will be changed to 225.
_ _ 15 will be changed to 214.
_ _ 16 will be changed to 205.
_ _ 17 will be changed to 196.
_ _ 18 will be changed to 188.
_ _ 19 will be changed to 180.
_ _ 1A will be changed to 173.
_ _ 1B will be changed to 167.
_ _ 1C will be changed to 160.
_ _ 1D will be changed to 155.
_ _ 1E will be changed to 150.
_ _ 1F will be changed to 145.
_ _ 00 will be changed to _ _ _ 0.
_ _ _ X
Otherwise, _ _ _ 1 will be set.
_ _ X_
The setting value will be maintained.