Part 9: Review on Replacement of Optional Peripheral Equipment

7.6 MR-J4-Series Power Factor Improving AC Reactor (200 V/100 V class)

The following shows the advantages of using power factor improving AC reactor.
• It improves the power factor by increasing the form factor of the servo amplifier's input current.
• It decreases the power supply capacity.
• The input power factor is improved to about 80%.
When using power factor improving reactors for two servo amplifiers or more, make sure to connect a power
factor improving reactor to each servo amplifier. If using only one power factor improving reactor, enough
improvement effect of phase factor cannot be obtained unless all servo amplifiers are operated.
4-d mounting hole
(Varnish is removed from front right mounting
hole (face and back side).) (Note 1)
W1
W or less (Note 2)
Note 1. Use this for grounding.
2. W ± 2 is applicable for FR-HAL-0.4K to FR-HAL-1.5K.
4-d mounting hole
(Varnish is removed from front right mounting
hole (face and back side).) (Note)
W1
W ± 2
Figure 9.5
Note.
Use this for grounding.
Terminal layout
R X
S Y T
Z
D or less
D2
D1
Fig. 9.4
Terminal layout
R X
S Y T
Z
D or less
D2
D1
MCCB
3-phase
200 V AC to
240 V AC
MCCB
(Note)
1-phase
200 V AC to
240 V AC
MCCB
1-phase
100 V AC to
120 V AC
Note. For 1-phase 200 V AC to 240 V AC, connect the power
supply to L1 and L3. Leave L2 open.
R
S
X
Y
W1
W or less
Note. Use this for grounding.
9 - 43
Servo amplifier
3-phase 200 V class
FR-HAL
MC
R
X
L1
S
Y
L2
T
Z
L3
Servo amplifier
1-phase 200 V class
FR-HAL
MC
R
X
L1
S
Y
L2
T
Z
L3
Servo amplifier
1-phase 100 V class
FR-HAL
MC
R
X
L1
S
Y
Unassigned
T
Z
L2
4-d mounting hole (Note)
D or less
T
Z
D2
D1 ± 2
Fig. 9.6