Part 5: Review on Replacement of MR-J2S-30 kW or Higher Capacity Models with MR-J4-DU_
Part 5: Review on Replacement of MR-J2S-30 kW or Higher Capacity Models with
MR-J4-DU_
1. FUNCTIONS AND CONFIGURATION
1.1 Differences Between MR-J2S-30 kW or Higher Capacity Models and MR-J4-DU_
Item
Converter unit
200 V class: MR-HP30KA
(When using a servo amplifier of
37 kW, make sure that the
power running output is 30 kW
or less.)
400 V class: MR-HP55KA4
Installation
Installed in cabinet
(Using an outside mounting
attachment enables to attach a
heat sink outside the cabinet.)
Magnetic contactor
Not available
control
Connector
Unit
Not available
Power consumption
display
SEMI-F47 function
Not available
selection
MR-J2S-30 kW or more
series
MR-J4-DU_ series
200 V class: MR-CR55K
400 V class: MR-CR55K4
A heat sink is attached outside
the cabinet.
Available
(Enabled by default. This is the
initial value of [Pr. PA02], a
converter unit parameter.)
Available
(Use converter unit parameters
[Pr. PA08] and [Pr. PA15] to set
this value.)
Available
(Use converter unit parameter
[Pr. PA17] and [Pr. PA18], and
drive unit parameter [Pr. PA20]
and [Pr. PF25] to set this value.)
5 - 2
Compatibility Reference material/items
1.2 Combination of a
×
Converter Unit, Drive
Unit, and Servo Motor
1.4 Installation
×
-
1.5 Magnetic Contactor
Control Connector
(CNP1) [Exclusively for
MR-J4-DU_]
-
3 PARAMETERS
-
3 PARAMETERS