Mitsubishi Electric MELSERVO-J2S Series Transition Handbook page 197

Servo amplifiers & motors
Hide thumbs Also See for MELSERVO-J2S Series:
Table of Contents

Advertisement

Part 5: Review on Replacement of MR-J2S-30 kW or Higher Capacity Models with MR-J4-DU_
(2) Selection example of crimp terminals
The table below shows selection examples of crimp terminals for a terminal block of a drive unit or
converter unit when the wires described in (1) of this section are used.
Symbol
Crimp terminal
(Note 2)
a
FVD5.5-10
b
FVD22-10
c
R38-10
(Note 1)
d
R60-10
(Note 1)
e
FVD22-8
f
R38-8
(Note 1)
g
FVD2-4
Note 1. Cover the crimped portion with an insulating tape.
2. Installation of a crimp terminal may be impossible depending on the size, so make sure to
use the recommended crimp terminal or one equivalent to it.
Drive unit/converter unit side crimp terminal
Applicable tool
Body
Head
YNT-1210S
YF-1
YNE-38
E-4
YPT-60-21
YF-1
YET-60-1
E-4
YPT-60-21
YF-1
YET-60-1
E-4
YF-1
YNE-38
E-4
YPT-60-21
YF-1
YET-60-1
E-4
YNT-1614
5 - 36
Dice
Manufacturer
DH-123
DH-113
TD-124
TD-112
TD-125
JST
TD-113
DH-123
DH-113
TD-124
TD-112

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMelservo-j2m seriesMelservo-j4 seriesMr-j2s-10aMr-j2s-20aMr-j2s-40a ... Show all