Part 9: Review on Replacement of Optional Peripheral Equipment
4.3.2 MR-J4 series, molded-case circuit breakers, fuses, and magnetic contactors (recommended)
(1) For main circuit power supply
CAUTION
When using a fuse instead of the molded-case circuit breaker, use the one having the specifications given in
this section.
Molded-case circuit breaker (Note 1)
Servo amplifier
Frame, rated current
MR-J4-10_(-RJ)
30 A frame 5 A
MR-J4-20_(-RJ)
MR-J4-40_(-RJ)
30 A frame 10 A
MR-J4-60_(-RJ)
MR-J4-70_(-RJ)
30 A frame 15 A
MR-J4-100_(-RJ)
MR-J4-200_(-RJ)
30 A frame 20 A
MR-J4-350_(-RJ)
30 A frame 30 A
MR-J4-500_(-RJ)
50 A frame 50 A
MR-J4-700_(-RJ)
100 A frame 75 A
MR-J4-11K_(-RJ)
100 A frame 100 A
MR-J4-15K_(-RJ)
125 A frame 125 A
MR-J4-22K_(-RJ)
225 A frame 175 A
MR-J4-10_1(-RJ)
30 A frame 5 A
MR-J4-20_1(-RJ)
30 A frame 10 A
MR-J4-40_1(-RJ)
30 A frame 15 A
Note 1. In order for the servo amplifier to comply with the UL/CSA standard, refer to the applicable "Servo Amplifier Instruction
Manual".
2. Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80 ms or less.
3. S-N18 can be used when auxiliary contact is not required.
Molded-case circuit breaker (Note 1, 3)
Servo amplifier
Frame, rated current
MR-J4-60_4(-RJ)
30 A frame 5 A
MR-J4-100_4(-RJ)
30 A frame 10 A
MR-J4-200_4(-RJ)
30 A frame 15 A
MR-J4-350_4(-RJ)
30 A frame 20 A
MR-J4-500_4(-RJ)
30 A frame 20 A
MR-J4-700_4(-RJ)
30 A frame 30 A
MR-J4-11K_4(-RJ)
50 A frame 50 A
MR-J4-15K_4(-RJ)
60 A frame 60 A
MR-J4-22K_4(-RJ)
100 A frame 100 A
Note 1. In order for the servo amplifier to comply with the UL/CSA standard, refer to the applicable "Servo Amplifier Instruction
Manual".
2. Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80 ms or less.
3. Use a molded-case circuit breaker with operating characteristics equivalent or higher than our multi-purpose product.
Select a molded-case circuit breaker with a short shut-off time to prevent smoking
and fire from the servo amplifier.
Always use one molded-case circuit breaker and one magnetic contactor with one
servo amplifier.
Molded-case circuit breakers, fuses, and magnetic contactors
Voltage AC [V]
240
Voltage AC [V]
480
Fuse
Class
Current [A]
10
15
20
40
T
70
125
150
200
250
350
10
15
20
Fuses
Class
Current [A]
10
15
25
35
50
T
65
100
150
175
9 - 21
Magnetic
contactor
Voltage AC [V]
(Note 2)
S-N10
S-T10
S-N20 (Note 3)
S-T21
S-N20
300
S-T21
S-N35
S-N50
S-N65
S-N95
S-N10
S-T10
Magnetic
contactor
Voltage AC [V]
(Note 2)
S-N10
S-T10
S-N18
S-T21
600
S-N20
S-T21
S-N25
S-N35
S-N50