Cisco ONS 15454 Troubleshooting Manual page 538

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

Table 4-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-6277
There are no alarm conditions available to run APC Correction
Skipped Override.
EID-6278
APC Correction Skipped Override is not supported for this
card.
EID-6279
Protection cannot be disabled when the FPAS alarm is active.
WID-6280
Any configuration change will be lost and the operation is
traffic affecting.
EID-6281
The port is involved in a protection group.
The protected port is not in the {0} administrative state
WID-6282
Forcing FPGA update will be traffic-affecting.
WID-6283
Enabling ALS on a DWDM trunk port that is connected to a
channel filter
will result in a conflict with the ALS on the amplifier card or
with the
VOA startup process. Is it OK to continue?
WID-6284
Changing the timing standard will re-initialize the shelf timing
and might affect traffic.
OK to continue?
WID-6285
Since you are changing the IP address of one node containing
some PPC terminations,
you are also requested to run the PPC Repair tool in order to fix
the IP addresses stored
in the nodes connected by these PPCs
EID-6286
The port type cannot be changed because the port has been
deleted.
EID-6287
You cannot edit the {0} {1}.
EID-6288
The BERT configuration is invalid.
EID-6289
The BERT mode is not yet configured
WID-6290
The BERT mode is configured in unframed format
WID-6291
Port has circuits; configuring the BERT mode will disrupt
normal traffic.
EID-6292
The alarm type name cannot exceed 20 characters
EID-6294
The alarm type name contains invalid characters.
Only the following characters are valid: 0-9, A-z, a-z and "-".
EID-6295
The alarm type is in use and cannot be deleted.
EID-6296
Maximum number of alarm types that can be added cannot
exceed 50.
EID-6297
Hard coded alarm types cannot be deleted.
Cisco ONS 15454 Troubleshooting Guide, R8.5
4-50
Chapter 4
Description
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Change the port state to administrative.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Port rate of Optical and Electrical ports
cannot be changed while circuits are
provisioned on them.
Refer to the eror message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Error Messages
November 2009

Advertisement

Table of Contents