Cisco ONS 15454 Troubleshooting Manual page 435

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

Chapter 2
Alarm Troubleshooting
Clear the SYNCLOSS Alarm
Ensure that the data port connection at the near-end card's port of the SONET link is operational.
Step 1
Verify fiber continuity to the port. To do this follow site practices.
Step 2
View the physical port LED to determine whether the alarm has cleared:
Step 3
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 4
for more information or call Cisco TAC 1 800 553-2447 to report a Service-Affecting (SA) problem.
2.7.408 SYNCPRI
A Loss of Timing on Primary Reference alarm occurs when the ONS 15454 loses the primary timing
source (reference 1). The ONS 15454 uses three ranked timing references. The timing references are
typically two BITS-level or line-level sources and an internal reference. If SYNCPRI occurs, the
ONS 15454 should switch to its secondary timing source (reference 2). Switching to the secondary
timing source also triggers the
Clear the SYNCPRI Alarm
In node view, click the Provisioning > Timing > General tabs.
Step 1
Verify the current configuration for REF-1 of the NE Reference.
Step 2
If the primary timing reference is a BITS input, complete the
Step 3
on page
If the primary reference clock is an incoming port on the ONS 15454, complete the
Step 4
(OCN) Alarm" procedure on page
Step 5
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC 1 800 553-2447.
November 2009
If the LED is green, the alarm has cleared.
If the port LED is clear (that is, not illuminated green), the link is not connected and the alarm has
not cleared.
If the LED is red, this indicates that the fiber is pulled.
Default Severity: Minor (MN), Non-Service-Affecting (NSA) for EXT-SREF;Major (MJ),
Service-Affecting (SA) for NE-SREF
SONET Logical Objects: EXT-SREF, NE-SREF
The SYNCPRI alarm will be escalated to Major (MJ), Service-Affecting if no other valid
Note
references (SYNCSEC, SYNCTHIRD) are available. If any other reference are available
then SYNCPRI gets raised as Minor (MN), non service affecting.
2-158.
"SWTOSEC" alarm on page
2-165.
Cisco ONS 15454 Troubleshooting Guide, R8.5
2.7.408 SYNCPRI
2-239.
"Clear the LOS (BITS) Alarm" procedure
"Clear the LOS
2-241

Advertisement

Table of Contents
loading

Table of Contents