Table 4-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
WID-2165
The MAC address of the node {0} has been changed. All
circuits originating from or dropping at this node will need to
be repaired.
WID-2166
The node cannot be inserted into the domain because it is not
initialized.
WID-2167
You have insufficient security privileges to perform this action. You do not have the privilege to perform
WID-2168
The following warnings surfaced while loading {0}.
{1}
WID-2169
One or more of the profiles selected do not exist on one or more
of the nodes selected.
WID-2170
The profile list on node {0} is full. Please delete one or more
profiles if you wish to add the profile.
{1}
WID-2171
You have been logged out. Click OK to exit CTC.
WID-2172
The CTC CORBA (IIOP) listener port setting of {0} will be
applied on the next CTC restart.
EID-2173
The port is unavailable.
The desired CTC CORBA ({0}) listener port, {1}, is already in
use or you do not have permission to listen on it. Please select
an alternate port.
EID-2174
An invalid number was entered. Please check it and try again.
WID-2175
An extension byte mismatch occurred.
{0}
WID-2176
Not all spans have the same OSPF area ID.
This will cause problems with protection switching. To
determine the OSPF area for a given span, click on the span and
the OSPF area will be displayed in the pane to the left of the
network map.
WID-2178
Only one edit pane can be opened at a time. The existing pane
will be displayed.
WID-2179
No update is available because the circuit has been deleted.
EID-2180
The CTC initialization failed during step {0}.
EID-2181
This link cannot be included because it originates from the
destination.
EID-2182
The value of {0} is invalid.
Cisco ONS 15454 Troubleshooting Guide, R8.5
4-12
Chapter 4
Description
Repair the circuits that originate from or
drop at the specified node, with the new
MAC address.
Initialize the node and proceed.
this action.
CTC encountered warnings while loading
the alarm profile import file.
The profile selected does not exist on the
node. Select another profile.
The number of profile that can exist on a
node has reached the limit. To add a profile,
delete any of the existing profiles.
Refer to the warning message text.
The Internet Inter-ORB Protocol (IIOP)
listener port setting for the CTC Common
Object Request Broker Architecture
(CORBA) will be applied on the next CTC
restart.
Select an alternate port, as the current port
is either in use or you do not have enough
permission on it.
You entered an invalid firewall port number.
Try again.
There is a mismatch with the extension
byte.
Refer to the warning message text.
Refer to the warning message text.
Refer to the warning message text.
CTC initialization has failed in the specified
step.
You must not include this link as it
originates from destination of a circuit. It is
against the path selection algorithm.
The value of the specified item is invalid.