3.3.37 WORK-QUEUE-FULL
3.3.37 WORK-QUEUE-FULL
The Work Queue Full(WORK-QUEUE-FULL) condition occurs when the netTask Queue in VxWorks
has filled up and task operations for the card are postponed.
This transient condition does not result in a standing condition.
3.3.38 WKSWBK
The Switched Back to Working (WKSWBK) condition occurs when traffic switches back to the working
port/card in a non-revertive protection group.
This transient condition does not result in a standing condition.
3.3.39 WKSWPR
The Switched to Protection (WKSWPR) condition occurs when traffic switches to the protect port/card
in a non-revertive protection group. This transient condition does not result in a standing condition. The
(WKSWPR) is raised as a standing condition in a revertive protection group.
The Switched to Protection (WKSWPR) condition also occurs after the protection switch in a 1+1
non-revertive protection group as a transient condition. When the protection group is changed to
revertive, the (WKSWPR) is not raised as a standing condition or as a new transient condition. However,
after a protection switch in a 1:1 protection group, the user will not be allowed to configure the protection
group from non-revertive to revertive.
3.3.40 WTR-SPAN
The Span is in Wait To Restore State (WTR-SPAN) condition occurs when a BLSR switches to another
span due to a Signal Failure-Span command or a fiber is pulled from a four-fiber BLSR configuration.
The condition is raised until the WaitToRestore (WTR) period expires.
This transient condition clears when the BLSR returns to a normal condition or the IDLE state.