Table 4-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-5039
Provisionable patchcords created between transponder trunk
ports and multiplexer/demultiplexer ports must use the same
wavelength:
{0} is not equal to {1}.
Please provision the {2} wavelength on {3}.
EID-5040
Provisionable patchcords created between OC3/OC12 ports and
multiplexer/demultiplexer ports are not supported.
EID-5041
Provisionable patchcords created between gray OC-N trunk
ports and multiplexer/demultiplexer ports are not supported.
EID-5042
Provisionable patchcords created between OC-N trunk ports
and multiplexer/demultiplexer ports must use the same
wavelength:
{0} is not equal to {1}.
WID-5043
Warning: Only the line card was provisioned.
The wavelength compatibility check was skipped.
EID-5044
Virtual links can be used only for OCH-Trail circuits.
EID-5045
The virtual link does not have wavelengths available.
WID-5046
Warning: if you select "Use OCHNC Direction," your circuit
will be limited to nodes prior to release 07.00.
EID-5047
Provisionable patchcords created between OC3/OC12 ports are
not supported.
EID-5048
Provisionable patchcords created between gray OC-N trunk
ports are not supported.
EID-5049
Provisionable patchcords created between gray OC-N trunk
ports and multiplexer/demultiplexer ports are not supported.
EID-5050
The element model could not be found.
{0}
WID-5051
The port state cannot be indirectly transitioned because the port
aggregates OCHCC circuits: if the port state needs to be
changed, edit it directly through port provisioning.
EID-5052
The operation is not valid for the connection type.
EID-5053
The operation cannot be performed because the connection is
under test access.
EID-5054
The TL1 tunnel could not be opened. {0}
EID-5055
Some patchcords were not deleted. Patchcords cannot be
deleted if they are incomplete or support any circuits, or if the
nodes supporting them are not connected.
EID-5056
This PPC cannot be deleted because one or more circuits are
provisioned over it.
Cisco ONS 15454 Troubleshooting Guide, R8.5
4-36
Chapter 4
Description
Transmitter and receiver port wavelengths
are not equal. Provision the receiver and
transmitter wavelengths on transmitter and
receiver ports respectively.
Refer to the error message text.
Refer to the error message text.
Wavelengths used by provisionable
patchcords for OC-N trunk ports and
mux/demux ports must be the same.
Refer to the warning message text.
Refer to the error message text.
Set wavelengths for the virtual link and
proceed.
Refer to the warning message text.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
The specified Element Model cannot be
located.
Refer to the warning message text.
You may have selected the incorrect switch.
Refer to the error message text.
Refer to the error message text.
Refer to the error message text.
Remove the circuits provisioned over the
provisionable patchcord before trying to
delete it.
Error Messages