Cisco ONS 15454 Troubleshooting Manual page 272

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

2.7.77 DS3-MISM
Clear the DISCONNECTED Alarm
Restart CTC.
Step 1
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 2
for more information or call TAC (1-800-553-2447).
2.7.77 DS3-MISM
The DS-3 Frame Format Mismatch condition indicates a frame format mismatch on a signal transiting
the ONS 15454 DS3XM-6, DS3XM-12, or DS3/EC1-48 card. The condition occurs when the
provisioned line type and incoming signal frame format type do no match. For example, if the line type
for a DS3XM-6 card is set to C Bit and the incoming signal frame format is detected as M13, then the
ONS 15454 reports a DS3-MISM condition.
Clear the DS3-MISM Condition
Display the CTC card view for the reporting DS3E-12, DS3I-12, DS3XM-6, DS3XM-12, or
Step 1
DS3/EC1-48 card.
Click the Provisioning > Line tabs.
Step 2
For the row on the appropriate port, verify that the Line Type column is set to match the expected
Step 3
incoming signal (C Bit or M13).
If the Line Type field does not match the expected incoming signal, select the correct Line Type in the
Step 4
drop-down list.
Step 5
Click Apply.
If the condition does not clear after the user verifies that the provisioned line type matches the expected
Step 6
incoming signal, use an optical test set to verify that the actual signal coming into the ONS 15454
matches the expected incoming signal. For specific procedures to use the test set equipment, consult the
manufacturer.
If the condition does not clear, log into the Technical Support Website at
Step 7
http://www.cisco.com/techsupport for more information or call Cisco TAC 1 800 553-2447.
2.7.78 DSP-COMM-FAIL
For information about this alarm or condition, refer to the "Alarm Troubleshooting" in the
Cisco ONS 15454 DWDM Troubleshooting Guide. This guide discusses all DWDM alarms.
Cisco ONS 15454 Troubleshooting Guide, R8.5
2-78
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Object: DS3
Chapter 2
Alarm Troubleshooting
November 2009

Advertisement