d.
Full-duplex, 1000Mb/s, Gbic not connected, Auto-negotiation
output flow-control is off, input flow-control is on
View the autonegotiation configuration for the partner node. If it is ONS equipment, follow the previous
Step 3
step for this node. If the node is different vendor client equipment, follow that equipment documentation
to obtain the information.
If the alarm does not clear, check for any fiber breaks such as on the transmit cable from the partner node
Step 4
to the near-end node.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 5
for more information or call Cisco TAC 1 800 553-2447 to report a Service-Affecting (SA) problem.
2.7.30 AUTORESET
The Automatic System Reset alarm occurs when you change an IP address or perform any other
operation that causes an automatic card-level reboot. AUTORESET typically clears after a card reboots
(up to ten minutes).
Resets performed during a software upgrade also prompt the condition. This condition clears
automatically when the card finishes resetting. If the alarm does not clear, complete the following
procedure.
Clear the AUTORESET Alarm
Step 1
Determine whether there are additional alarms that could have triggered an automatic reset. If there are,
troubleshoot these alarms using the applicable section of this chapter.
If the card automatically resets more than once a month with no apparent cause, complete the
Step 2
Replace a Traffic Card" procedure on page
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 3
for more information or call Cisco TAC 1 800 553-2447.
2.7.31 AUTOSW-AIS
The Automatic Path Protection Switch Caused by an AIS condition indicates that automatic path
protection switching occurred because of an AIS condition. If the path protection is configured for
revertive switching, it reverts to the working path after the fault clears. The AIS also clears when the
upstream trouble is cleared.
November 2009
View the command output and record the autonegotiation setting, such as the following example:
Default Severity: Minor (MN), Non-Service-Affecting (NSA)