Chapter 2
Alarm Troubleshooting
For information about provisioning the ML-Series Ethernet cards from the Cisco IOS interface, refer to
Note
the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration
Guide.
Clear the ERROR-CONFIG Alarm
If you have a different type of ML-Series card specified in the startup configuration file than what you
Step 1
have installed, create the correct startup configuration.
Follow the card provisioning instructions in the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet
Card Software Feature and Configuration Guide.
Upload the configuration file to the TCC2/TCC2P:
Step 2
a.
b.
c.
Complete the
Step 3
If the alarm does not clear or if your configuration file was correct according to the installed card, start
Step 4
a Cisco IOS CLI for the card:
a.
b.
Follow the card provisioning instructions in the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet
Card Software Feature and Configuration Guide to correct the errored configuration file line.
Execute the CLI command:
Step 5
router(config)#copy run start
The command copies the new card configuration into the database and clears the alarm.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 6
for more information or call Cisco TAC 1 800 553-2447.
2.7.95 ETH-LINKLOSS
November 2009
The user stored the configuration for one type of ML-Series card in the database and then installed
another type in its slot.
The configuration file contained a syntax error on one of the lines.
The user stored the configuration for the ML-Series card and then changed the card mode from
RPR-IEEE mode to another mode, or vice versa.
In node view, right-click the ML-Series card graphic.
Choose IOS Startup Config from the shortcut menu.
Click Local > TCC and navigate to the file location in the Open dialog box.
"Reset a Traffic Card in CTC" procedure on page
Right click the ML-Series card graphic in node view.
Choose Open IOS Connection from the shortcut menu.
Open IOS Connection is not available unless the ML-Series card is physically installed in
Note
the shelf.
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
2-270.
Cisco ONS 15454 Troubleshooting Guide, R8.5
2.7.95 ETH-LINKLOSS
2-89