Cisco ONS 15454 Troubleshooting Manual page 498

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

Table 4-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-2123
Verify that the following nodes have at least two in-service
ports with the same speed as the two-fiber {0}. The ports cannot
serve as timing references, and they cannot have DCC
terminations or overhead circuits.
{1}
EID-2124
You cannot add this span because it is connected to a node that
already has the east and west ports defined.
EID-2125
You cannot add this span as it would cause a single card to host
both the east span and the west span. A card cannot protect
itself.
EID-2126
An error occurred while provisioning the OSPF area.
{0}
EID-2127
You cannot add this span. It would cause the following
circuit(s) to occupy different {0} regions on different spans:
{1}
Either select a different span or delete the above circuit(s).
EID-2128
The state is invalid.
EID-2129
You cannot use same slot for east and west protect ports.
EID-2130
The ring ID value, {0}, is not valid. Please enter a valid number
between 0 and 9999.
EID-2131
The reversion cannot be set to INCONSISTENT.
EID-2135
The overhead circuit preferences could not be stored:
{0}
EID-2137
An error occurred during the circuit merge.
{0}
EID-2138
Not all destinations could be deleted.
Please try again.
EID-2139
An error occurred while updating the destinations.
EID-2143
No online help version was selected.
The online help book cannot be deleted.
EID-2144
An error occurred while deleting the online help book(s).
{0}
EID-2145
No nodes appear to have a Cisco IOS card.
EID-2146
This is a security violation.
You may only logout of your own account.
Cisco ONS 15454 Troubleshooting Guide, R8.5
4-10
Chapter 4
Description
Nonupgradable nodes. Verify that the
specified nodes have at least two IS-NR
ports with the same speed as the 2-fiber
BLSR.
The specified ports cannot serve as a timing
reference, and they cannot have data
communications channel (DCC)
terminations or overhead circuits.
Refer to the error message text.
Refer to the error message text.
There is an Open Shortest Path First (OSPF)
area error.
A circuit cannot occupy different STS
regions on different spans. You may add a
different span or delete the specified circuit.
An internal error occurred while trying to
remove a span from a BLSR.
This alarm occurs in the network-level
BLSR creation dialog box.
Refer to the error message text.
Enter a ring ID value between 0 and 9999.
You must select another reversion type.
Input/Output error. Unable to store
overhead circuit preferences.
There was an error while merging the
circuits.
Refer to the error message text.
There was an error in updating the circuit
destinations.
Select the version of online help, and
proceed.
You cannot delete the specified online help.
Refer to error message.
You cannot logout of an account other than
your own.
Error Messages