Error Messages
Table 4-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-5024
The overhead circuit will not be upgraded.
WID-5025
The path targeted for this switch request is already active. The
switch request can be applied, but traffic will not switch at this
time.
EID-5026
An ONS 15600 cannot serve as the primary or secondary node
in a four-fiber {0} circuit. Please change your ring and/or node
selections so that an ONS 15600 is not chosen as the primary or
secondary node in this four-fiber {1} circuit.
WID-5027
The {0} Edit dialog box for the ring {1} has been closed due to
significant provisioning changes. These changes might only be
transitory, so you can reopen the {0} Edit dialog box to view the
updated state.
WID-5028
Warning: This operation should only be used to clean up rolls
that are stuck. It might also affect completeness of the circuit.
Is it OK to continue with the deletion?
EID-5029
A software downgrade cannot be performed to the selected
version while an SSXC card is inserted in this shelf. Please
follow the steps to replace the SSXC with a CXC card before
continuing the software downgrade.
EID-5030
A software downgrade cannot be performed at the present time. Try the software downgrade later.
WID-5031
Canceling a software upgrade during a standby TSC clock
acquisition might result in a traffic outage.
EID-5032
An error occurred while accepting the load.
EID-5033
The profile could not be loaded.
An error occurred while decoding the characters.
EID-5034
The profile could not be loaded.
An error occurred while trying to recognize the file format.
EID-5035
The profile could not be loaded.
An error occurred while reading the file.
EID-5036
The GNE hostname {0} is invalid.
EID-5037
Provisionable patchcords cannot be created between
transponder trunk ports and multiplexer/demultiplexer ports on
the same node.
EID-5038
Provisionable patchcords created between transponder trunk
ports and multiplexer/demultiplexer ports must use the same
wavelength:
{0} is not equal to {1}.
November 2009
Description
Refer to the error message text.
Refer to the warning message text.
Refer to the error message text.
Re-open the BLSR/MS-SPRing edit
window to view the updated state of the
ring.
Refer to the warning message text.
Refer to the error message text.
Refer to the warning message text.
Refer to the error message text.
CTC detected an error while decoding
characters and could not load the profile.
CTC detected an error and could not load
the profile.
CTC could not read the file and is therefore
unable to load the profile.
The specified host name is invalid. CTC
could not resolve the host name to any valid
IP address
You must create provisionable patchcords
between transponder trunk ports and
mux/demux ports that are on different
nodes.
Wavelengths used by provisionable
patchcords for transponder trunk ports and
mux/demux ports must be the same.