Error Messages
Table 4-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-3235
The requested state transition cannot be performed on this
software version.
EID-3236
The database restore failed. {0}
EID-3237
The database backup failed. {0}
EID-3238
The send PDIP setting on {0} is inconsistent with the setting on
the control node {1}.
EID-3239
The overhead termination is invalid
EID-3240
The maximum number of overhead terminations has been
exceeded.
EID-3241
The {0} termination port is in use.
EID-3242
An {1} exists on the selected ports.
Therefore, you must create the {0}s one by one.
WID-3243
The port you have chosen as an {0} endpoint already supports
an {1}. The port cannot support both DCCs. After the {0} is
created, verify that no EOC alarms are present and then delete
the {1} to complete the downgrade.
EID-3244
An {0} exists on the selected ports.
Therefore, you must create the {1}s one by one.
WID-3245
The port you have chosen as an {1} endpoint already supports
an {0}. The port cannot support both DCCs. After the {1} is
created, verify that no EOC alarms are present and then delete
the {0} to complete the upgrade.
EID-3246
The wizard was not able to validate the data.
{0}
EID-3247
An ordering error occurred. The absolute value should be {0}. The absolute value entered was wrong.
EID-3248
The value for the parameter {0} is invalid.
EID-3249
The voltage increment value is invalid.
EID-3250
The power monitor range is invalid.
EID-3251
The requested action could not be completed.
{0}
EID-3252
No download has been initiated from this CTC session.
EID-3253
The reboot operation failed. {0}
November 2009
Description
Refer to the error message text.
CTC failed to restore the specified
database.
CTC failed to backup the specified
database.
The send payload defect indicator path
(PDI-P) setting on the specified item should
be consistent with that of the specified
control node.
Refer to the error message text.
Overhead terminations have exceeded the
limit.
The specified termination port is in use.
Select another port.
The specified DCC already exists on the
selected port. You can create a DCC of
another type.
The same port can not be used by multiple
DCCs.
The specified DCC already exists on the
selected port. You can create a DCC of
another type.
The port selected as a DCC endpoint
already supports another DCC. Refer to the
warning message text.
CTC encountered an error.
CTC changed the incorrect parameter.
Refer to the error message text.
Refer to the error message text.
CTC could not complete the specified
action.
Refer to the error message text.
Refer to the error message text.
Cisco ONS 15454 Troubleshooting Guide, R8.5