MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Table 3-8: Typical Quality data attribute values in UR devices
Containing
Any minor
logical node's
error
Beh.stVal
(FlexLogic
operand)
on
Off
on
On
on-blocked
any
test
Off
test
On
test/blocked
Off
3
test/blocked
On
off
any
Many of the UR family device elements have multiple instances, and in many cases the number of instances depends on
the product or the device's order code. Also, many UR elements have operands and/or settings that are repetitive, such as
for every phase, or for every step. Again for brevity, in the following information model outline a template representing
multiple logical nodes or multiple data objects is often used. These templates are identified with a Greek or punctuation
character, such as γ or #, in the logical node/data object name. In a UR device, the template is instantiated multiple times
with the punctuation or Greek character replaced with the appropriate instance number or instance identifier.
The R/W/C column in the following tables is coded as follows:
R — Value of the data object or data attribute is readable via MMS services
W — Value of the data object or data attribute is writable via MMS services
C — Value of the data object or data attribute is configurable via SCL file download
Ctrl — The data object can be controlled via MMS services
The logical nodes implemented in UR devices since version 7.30 are sorted into six logical devices. The table outlines the six
logical devices and the general rules for the fixed assignment of logical nodes to them. Each logical device has a section in
this chapter that defines the logical nodes implemented for that logical device. In UR 7.40 and later, new LDevice elements
other than those originally in the Master logical device can be moved between LDevice elements, and LDevice elements
containing no LN elements can be removed.
Table 3-9: Logical devices
Logical device
Master
Protection (Prot)
Control (Ctrl)
System
Metering (Meter)
General (Gen)

3.5.1 Master (root) logical device

The Master logical device contains communications-related logical nodes, including GOOSE, reports, log, and virtual inputs.
3-30
q.
q.
validity
test
good
false
questionable
false
invalid
false
good
true
questionable
true
invalid if ANY
true
MAJOR ERROR,
else good
invalid if ANY
true
MAJOR ERROR,
else questionable
invalid
false
Contains logical nodes modeling...
communications, including GOOSE, reports, Remote I/O, Direct I/O, Virtual Inputs, Modbus, DNP, and so on.
Setting group control.
This is the root logical device.
protection functions
control and monitoring functions
power system devices: breakers, switches, CTs, VTs, and so on, including interface to these such as AC inputs,
contact I/O, transducer I/O, HardFiber I/O
metering and measurement (other than PMU), including Signal Sources
FlexLogic, virtual outputs, non-volatile latches, FlexElements, FlexMath, recording (for example oscillography),
security, front panel, clock
CHAPTER 3: IEC 61850 COMMUNICATION
q.
q.
detailQual
source
0
process
0
process
0
process
0
process
0
process
0
process
0
process
0
process
UR FAMILY – COMMUNICATIONS GUIDE
q.
operatorblocked
false
false
true
false
false
false
false
false