GE B30 Communications Manual page 284

Ur family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
LNName: BusDifPDIF#
data obj. data attribute
Op
general
Dpo
stVal
DpoPhs1φ
stVal
DpoPhs2φ
stVal
OpPhs1φ
stVal
OpPhs2φ
3
stVal
PhDirφ
stVal
Satφ
stVal
DifAClc
phsθ
phsθ.instCVal
phsθ.instCVal.mag
.f
phsθ.instCVal.ang
.f
phsθ.cVal
phsθ.cVal.mag.f
phsθ.cVal.ang.f
phsθ.units
phsθ.units.SIUnit ENUMERATED
phsθ.units
.multiplier
phsθ.db
phsθ.dbAng
phsθ.zeroDb
angRef
RstA
phsθ
phsθ.instCVal
phsθ.instCVal.mag
.f
phsθ.instCVal.ang
.f
phsθ.cVal
phsθ.cVal.mag.f
phsθ.cVal.ang.f
phsθ.units
phsθ.units.SIUnit ENUMERATED
phsθ.units
.multiplier
phsθ.db
phsθ.dbAng
phsθ.zeroDb
3-46
LDevice inst: Prot
UR element: Bus Differential element # (ANSI 87B)
Type
FC UR Name
ACT
BOOLEAN
ST
BUS # OP
SPS
BOOLEAN
ST
BUS # DPO
SPS
BOOLEAN
ST
BUS # BIASED DPO θ
SPS
BOOLEAN
ST
BUS # UNBIASED DPO θ
SPS
BOOLEAN
ST
BUS # BIASED OP θ
SPS
BOOLEAN
ST
BUS # UNBIASED OP θ
SPS
BOOLEAN
ST
BUS # DIR θ
SPS
BOOLEAN
ST
BUS # SAT θ
WYE
CMV
Vector
MX
FLOAT32
BUS # DIFF Iθd magnitude, in
primary amps
FLOAT32
BUS # DIFF
Vector
MX
FLOAT32
BUS # DIFF Iθd magnitude, in
primary amps, with deadband
FLOAT32
BUS # DIFF
Unit
CF
ENUMERATED
INT32U
CF
BusDifPDIF#.DifAClc.phsθ.db
INT32U
CF
BusDifPDIF#.DifAClc.phsθ.dbAng
INT32U
CF
ENUMERATED
CF
WYE
CMV
Vector
MX
FLOAT32
BUS # REST Iθr magnitude, in
primary amps
FLOAT32
BUS # REXT
Vector
MX
FLOAT32
BUS # REST Iθr magnitude, in
primary amps, with deadband
FLOAT32
BUS # REST
Unit
CF
ENUMERATED
INT32U
CF
BusDifPDIF#.DifAClc.phsθ.db
INT32U
CF
BusDifPDIF#.DifAClc.phsθ.dbAng
INT32U
CF
CHAPTER 3: IEC 61850 COMMUNICATION
Description
BUS # OP operand
BUS # DPO operand
BUS # BIASED DPO θ operand
BUS # UNBIASED DPO θ operand
BUS # BIASED OP θ operand
BUS # UNBIASED OP θ operand
BUS # DIR θ operand
BUS # SAT θ operand
Phase differential currents
UR range -180...+180 converted to 0...360 R
UR range -180...+180 converted to 0...360 R
5, the code for amps
0, the code for a multiplier of 1
See UR product manual regarding
FREQUENCY AND PHASE REFERENCE
Phase restraint currents
UR range -180...+180 converted to 0...360 R
UR range -180...+180 converted to 0...360 R
5, the code for amps
0, the code for a multiplier of 1
UR FAMILY – COMMUNICATIONS GUIDE
R/W/C
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R/W/C
R/W/C
R
R
R
R
R
R
R
R
R
R
R
R/W/C
R/W/C
R