GE B30 Communications Manual page 454

Ur family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Data object
CDC
name
SntpFail
SPS
SPDTR
SPS
Spt
MV
Start
SPS
Starting
SPS
StlGMP
SPS
Stop
SPS
3
StrAccTm1
MV
StrAlm
ACD
StrBia
ACD
StrCls
SPS
StrEffA1
MV
StrHrLOTm
MV
StrInd
SPS
StrOpn
SPS
StrOutgoing
SPS
StrPeak1
MV
StrPhs1
SPS
StrRec3p
SPS
StrTD1
INS
StrZ2GndDl
SPS
StrZ2PhDl
SPS
StubBusOp
SPS
SumHa3NVZroV MV
SwFail
SPS
SysExcp
SPS
3-216
Semantics
SNTP server is not responding.
The SNTP FAILURE operand.
Motor switches from speed 2 to speed 1.
MOTOR SPD2 TR 2-1 OP operand.
Set point value. The PID 1 Setpoint value.
One-second pulse at set time of day timer # start time.
The TIME OF DAY 1 START operand.
Indicate the motor is starting.
The MOTOR STARTING operand.
Indicates status of IGMP connection for R-GOOSE multicast reception.
The R-RxGOOSE1 IGMP On operand.
One-second pulse at set time of day timer 1 stop time.
The TIME OF DAY 1 STOP operand.
Indicates motor start acceleration time. START 1 ACCELERATION TIME in seconds. MAccTmPMSS
Indicates the detection of a fault or an unacceptable condition.
The RRTD RTD 1 ALARM PKP operand.
The RTD Ip 1 ALARM PKP operand.
The U/CURR ALARM PKP operand.
The UNDERPWR 1 ALARM PKP operand.
B90 Start Biased indicates the detection of a fault or an unacceptable condition
by Biased Differential element
Close start indicates the pickup of close command, and its operation is pending.
The AVR 1 CLOSE PKP operands.
Indicates motor start effective current.
START 1 EFFECTIVE CURRENT in x FLA.
Start/Hour Lockout Time in minutes
An LED.
The LED PICKUP operand.
Open start indicates the pickup of open command, and its operation is pending.
AVR 1 OPEN PKP operands.
This Data Object indicates an unstable Power swing detection for outgoing Locus.
The POWER SWING OUTGOING operand.
Indicates motor start peak current.
START 1 PEAK CURRENT in x FLA.
Indicates the detection of a fault or an unacceptable condition on a particular
phase-to-phase loop.
The PHS DIST Z1 PKP AB/BC/CA operand in Phase-To-Phase.
Initiate a three-pole reclose.
The TRIP AR INIT 3-POLE operand.
Represents UTC timestamp for motor acceleration Time/DATE in seconds elapsed
since 00:00:00, 1970/01/01.
The START 1 TIME/DATE actual value.
Start zone 2 ground timer.
The TRIP Z2GR TMR INIT operand.
Start zone 2 phase timer.
The TRIP Z2PH TMR INIT operand.
The stub bus function is operated.
The STUB BUS OP operand, which becomes On when the Stub Bus function is
active.
Sum of third harmonic neutral voltage and zero sequence voltage.
The STATOR GND 3RD HARM VN+V0 in volts.
Autoreclose mode switching failed.
The AR MODE SWITCH FAIL operand.
System exception.
The SYSTEM EXCEPTION operand.
CHAPTER 3: IEC 61850 COMMUNICATION
Used in logical nodes...
LPHD
S2AcTmPMSS
PIDRegFPID
TmDayGAPC
MotThmPTTR
LGOS
TmDayGAPC
PRTDsSTMP, RRTDsSTMP,
UnCurPTUC, UnPwrPDUP
B_DifPDIF
AvrGAPC
MAccTmPMSS
StrRtePMRI
LEDsIHMI
AvrGAPC
PwrSwgRPSB
MAccTmPMSS
PhsDisPDIS
TrOutPTRC
MAccTmPMSS
TrOutPTRC
TrOutPTRC
LinDfPDIF
StatrPHIZ
Rec13pRREC
LPHD
UR FAMILY – COMMUNICATIONS GUIDE