MEMORY MAP
Products
Address Register name
"
68A4
"
68A6
"
68A8
"
68AA
2
"
68AB
"
68AC
"
68AD
"
68AE
"
68AF
"
68B0
"
68B1
"
68B2
"
68B3
"
68B4
"
68B6
"
68B8
"
68BA
"
68BC
"
68BE
"
68C0
"
68C2
"
68C4
"
68C5
"
68C6
Motor Acceleration Actuals (Read Only Non-Volatile) (5 Modules)
M60
68D0
"
68D2
"
68D3
"
68D5
"
68D7
"
68DF
"
68EE
"
68FD
"
690C
Motor Acceleration Commands (Read/Write Command)
M60
691F
Motor Maximum Starting Rate (Read/Write Setting)
M60
6920
"
6921
"
6922
"
6923
"
6925
2-96
Directional Comparison Unblocking Echo
Condition
DCUB Ground Directional Overcurrent
Forward
DCUB Ground Directional Overcurrent
Reverse
DCUB Transmit Block Pickup Delay
DCUB Transmit Block Reset Delay
Directional Comparison Unblocking Echo
Duration
Directional Comparison Unblocking Echo
Lockout
DCUB Line End Open Pickup Delay
DCUB Loss-of-Guard (Log) Pickup Delay
DCUB Guard Healthy Reset Delay
DCUB Loss-of-Guard Trip Window
Directional Comparison Unblocking Seal-In
Delay
Directional Comparison Unblocking
Communication Bits
Directional Comparison Unblocking Rx1
Directional Comparison Unblocking Log1
Directional Comparison Unblocking Rx2
Directional Comparison Unblocking Log2
Directional Comparison Unblocking Rx3
Directional Comparison Unblocking Log3
Directional Comparison Unblocking Rx4
Directional Comparison Unblocking Log4
Directional Comparison Unblocking Target 0 to 2
Directional Comparison Unblocking Event
Reserved (6 items)
Motor Acceleration 1 Time/Date
Motor Acceleration 1 Starting Time
Motor Acceleration 1 Effective Current
Motor Acceleration 1 Peak Current
Motor Acceleration 1 Reserved (8 items)
...Repeated for Motor Acceleration 2
...Repeated for Motor Acceleration 3
...Repeated for Motor Acceleration 4
...Repeated for Motor Acceleration 5
Motor Acceleration Clear Data Command
Starts Per Hour Function
Starts Per Hour Time Interval
Starts Per Hour Maximum Number of Starts 1 to 16
Starts Per Hour Block
Starts Per Hour Target
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 2
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
---
1
0 to 1
--
1
0 to 1
--
1
0 to 4294967295
---
1
0 to 655.35
s
0.01
0 to 999999.999
A
0.001 F060
0 to 999999.999
A
0.001 F060
---
---
---
0 to 1
---
1
0 to 1
---
1
1 to 300
min
1
---
1
0 to 4294967295
---
1
0 to 2
---
1
UR FAMILY – COMMUNICATIONS GUIDE
Format
Default
F300
0
F300
0
F300
0
20
90
100
250
50
8
15
150
10
F198
0 (1 bit)
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F109
0 (Self-Reset)
F102
0 (Disabled)
F001
0
F050
0
F001
0
0
0
F001
0
F126
0 (No)
F102
0 (Disabled)
F001
60
F001
3
F300
0
F109
0 (Self-reset)