CHAPTER 3: IEC 61850 COMMUNICATION
LNName: LinDfPDIF1
data obj. data attribute
Type
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRefγ05
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRefγ06
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRefγ07
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRefγ08
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRefγ09
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRefγ10
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRefγ12
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
InRefγ13
ORG
setSrcRef
ObjectReference SP
setSrcCB
ObjectReference SP
Table 3-57: Line current differential local terminal current data objects
LNName: LinDf0MMXU1
data obj. data attribute
Type
A
WYE
phsθ
CMV
phsθ.instCVal
Vector
phsθ.instCVal.mag
FLOAT32
.f
phsθ.instCVal.ang
FLOAT32
.f
phsθ.cVal
Vector
phsθ.cVal.mag.f
FLOAT32
phsθ.cVal.ang.f
FLOAT32
phsθ.units
Unit
phsθ.units.SIUnit ENUMERATED
phsθ.units
ENUMERATED
.multiplier
phsθ.db
INT32U
phsθ.dbAng
INT32U
UR FAMILY – COMMUNICATIONS GUIDE
LDevice inst: Prot
UR element: Line Differential element (ANSI 87L) phase and general
functions
FC UR Name
CURRENT DIFF BLOCK setting
CURRENT DIFF KEY DTT setting reference to the data attribute to input
STUB BUS DISCONNECT setting reference to the data attribute to input
STUB BUS TRIGGER setting
DD NON-CURRENT SUPV setting reference to the data attribute to input
DD CONTROL LOGIC setting
DD LOGIC SEAL-IN setting
87L TRIP SUPV setting
87L TRIP FORCE 3-φ setting
LDevice inst: Prot
UR element: Line Differential element (ANSI 87L) – local terminal current
function
FC UR Name
MX
LOCAL Iθ magnitude, in primary
amps
LOCAL Iθ an
MX
LOCAL Iθ magnitude, in primary
amps, with deadband
LOCAL Iθ an
CF
CF
LinDf0MMXU1.A.phsθ.db
CF
LinDf0MMXU1.A.phsθ.dbAng
MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Description
reference to the data attribute to input
source GoCB of input if via GOOSE
CURRENT DIFF KEY DTT setting of setting
group γ.
source GoCB of input if via GOOSE
STUB BUS DISCONNECT setting of setting
group γ.
source GoCB of input if via GOOSE
STUB BUS TRIGGER setting of setting
group γ.
reference to the data attribute to input
source GoCB of input if via GOOSE
DD NON-CURRENT SUPV setting.
source GoCB of input if via GOOSE
DD CONTROL LOGIC setting of setting
group γ.
reference to the data attribute to input
source GoCB of input if via GOOSE
DD LOGIC SEAL-IN setting of setting
group γ.
reference to the data attribute to input
source GoCB of input if via GOOSE
only instantiated in L90
reference to the data attribute to input
source GoCB of input if via GOOSE
only instantiated in L90
reference to the data attribute to input
source GoCB of input if via GOOSE
Description
Local terminal currents
UR range -180...+180 converted to 0...360 R
UR range -180...+180 converted to 0...360 R
5, the code for amps
0, the code for a multiplier of 1
R/W/C
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R
3
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R/W/C
R
R
R
R
R
R
R
R
R
R/W/C
R/W/C
3-65