MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
LNName: CBArc0SCBR#
data obj. data attribute
stVal
InRef1
setSrcRef
setSrcCB
BlkRef1
setSrcRef
setSrcCB
ColOpn
stVal
3
OpTmOpn
instMag
instMag.f
mag
mag.f
units
units.SIUnit
units.multiplier
db
zeroDb
MemClr
pulseConfig
pulseConfig
.cmdQual
pulseConfig.onDur INT32U
pulseConfig
.offDur
pulseConfig
.numPls
ctlModel
sboTimeout
sboClass
operTimeout
Table 3-141: Breaker arcing current phase data objects
LNName: CBArcΘSCBR#
data obj. data attribute
ColOpn
stVal
InRef1
setSrcRef
setSrcCB
AccAbr
instMag
instMag.f
mag
3-116
LDevice inst: Ctrl
UR element: BREAKER # ARCING CURRENT element
Type
FC UR Name
BOOLEAN
ST
BKR ARC # MAX DPO
ORG
ObjectReference SP
BKR # CLR ARC AMPS
ObjectReference SP
ORG
ObjectReference SP
BKR # ARC AMP BLOCK
ObjectReference SP
SPS
BOOLEAN
ST
Logical OR condition to
CBArc1SCBR#.ColOpn,
CBArc2SCBR#.ColOpn,
CBArc3SCBR#.ColOpn
MV
AnalogueValue
MX
FLOAT32
Mapped BKR # OPERATING TIME
Analogue Value MX
FLOAT32
instMag.f on deadband
exception
Unit
CF
ENUMERATED
ENUMERATED
INT32
CF
CBArc0SCBR#.OpTmOpn.db
INT32
CF
SPC
PulseConfig
CF
ENUMERATED
INT32U
INT32U
CtlModels
CF
CBArc0SCBR#.MemClr.ctlModel
INT32U
CF
SboClasses
CF
INT32U
CF
LDevice inst: Ctrl
UR element: BREAKER # ARCING CURRENT element
Type
FC UR Name
SPS
BOOLEAN
ST
Status value of mapped
FlexLogic operand in BKR # ARC
AMP INT- ψ setting
ORG
ObjectReference SP
BKR # ARC AMP INT- µ
ObjectReference SP
MV
AnalogueValue
MX
FLOAT32
BKR # ACC ARCING AMP ψ
Analogue Value MX
CHAPTER 3: IEC 61850 COMMUNICATION
Description
BKR # CLR ARC AMPS setting
reference to the data attribute to input
source GoCB of input if via GOOSE
BKR # ARC AMP BLOCK setting
reference to the data attribute to input
source GoCB of input if via GOOSE
Logical OR of status value of mapped
FlexLogic operands in BKR # ARC AMP
INT- A, BKR # ARC AMP INT- B, BKR # ARC
AMP INT- C
BKR # OPERATING TIME in ms
4, the code for Time (Sec)
-3, the code for a multiplier of 1/1000
0
CLEAR BREAKER # ARCING AMPS
command
0 (pulse)
2 ms (actually one pass)
0
1
30000
0 (operate-once)
0
Description
Status value of mapped FlexLogic
operand in BKR # ARC AMP INT- ψ
BKR # ARC AMP INT-µ setting
reference to the data attribute to input
source GoCB of input if via GOOSE
BKR # ACC ARCING AMP ψ in A2s
UR FAMILY – COMMUNICATIONS GUIDE
R/W/C
R
R
R/C
R/C
R
R/C
R/C
R
R
R
R
R
R
R
R
R
R
R/W/C
R
R/Ctrl
R
R
R
R
R
R/W/C
R
R
R
R/W/C
R
R
R
R/C
R/C
R
R
R
R

Advertisement

Table of Contents
loading

This manual is also suitable for:

D30D60F35F60G30G60 ... Show all

Table of Contents