GE B30 Communications Manual page 173

Ur family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

CHAPTER 2: MODBUS COMMUNICATION
Products
Address Register name
"
A8A4
DCB3 Dir Fwd1
"
A8A6
DCB3 Dir Fwd2
"
A8A8
DCB3 Dir Fwd3
"
A8AA
DCB3 Dir Rev1
"
A8AC
DCB3 Dir Rev2
"
A8AE
DCB3 Dir Rev3
"
A8B0
DCB3 Force Tx Stop1
"
A8B2
DCB3 Force Tx Stop2
"
A8B4
DCB3 Rx
"
A8B6
DCB3 Scheme Target
"
A8B7
DCB3 Scheme Events
Frequency Rate of Change (Read/Write Setting) (2 or 4 Modules)
D30, D60, F60,
A900
Frequency Rate of Change 1 Function
G30, G60, L30,
L90, N60, T60
"
A901
Frequency Rate of Change 1 OC
Supervision
"
A902
Frequency Rate of Change 1 Min
"
A903
Frequency Rate of Change 1 Max
"
A904
Frequency Rate of Change 1 Pickup Delay
"
A905
Frequency Rate of Change 1 Reset Delay
"
A906
Frequency Rate of Change 1 Block
"
A908
Frequency Rate of Change 1 Target
"
A909
Frequency Rate of Change 1 Events
"
A90A
Frequency Rate of Change 1 Source
"
A90B
Frequency Rate of Change 1 Trend
"
A90C
Frequency Rate of Change 1 Pickup
"
A90D
Frequency Rate of Change 1 OV
Supervision
"
A90E
Frequency Rate of Change 1 Reserved (3
items)
"
A911
...Repeated for Frequency Rate of Change 2
D60, F60, G30,
A922
...Repeated for Frequency Rate of Change 3
G60, L90, N60,
T60
"
A933
...Repeated for Frequency Rate of Change 4
Restricted Ground Fault (Read/Write Grouped Setting) (4 or 6 Modules)
F60, G30, G60,
A960
Restricted Ground Fault 1 Function
L90, T35, T60
"
A961
Restricted Ground Fault 1 Source
"
A962
Restricted Ground Fault 1 Pickup
"
A963
Restricted Ground Fault 1 Slope
"
A964
Restricted Ground Fault 1 Delay
"
A965
Restricted Ground Fault 1 Reset Delay
"
A966
Restricted Ground Fault 1 Block
"
A968
Restricted Ground Fault 1 Target
"
A969
Restricted Ground Fault 1 Events
"
A96A
...Repeated for Restricted Ground Fault 2
"
A974
...Repeated for Restricted Ground Fault 3
UR FAMILY – COMMUNICATIONS GUIDE
Range
Units
Step
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0.02 to 30
pu
0.001 F001
20 to 80
Hz
0.01
20 to 80
Hz
0.01
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 5
---
1
0 to 2
---
1
0.1 to 15
Hz/s
0.01
0.1 to 3
pu
0.001 F001
0 to 1
---
1
0 to 1
---
1
0 to 5
---
1
0.005 to 30
pu
0.001 F001
0 to 100
%
1
0 to 600
s
0.01
0 to 600
s
0.01
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
MEMORY MAP
Format
Default
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F102
0 (Disabled)
200
F001
4500
F001
6500
0
0
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F167
0 (SRC 1)
F224
0
(Increasing)
F001
50
700
F001
0
F102
0 (Disabled)
F167
0 (SRC 1)
80
F001
40
F001
0
F001
0
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
2-153
2