GE B30 Communications Manual page 181

Ur family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

CHAPTER 2: MODBUS COMMUNICATION
Products
Address Register name
IEC 61850 XSWI Configuration (Read/Write Command) (24 Modules)
All except B90
B256
Command to Clear XSWI OpCnt (Operation
Counter)
Wattmetric Ground Fault Settings (Read/Write Grouped) (2 or 4 Modules)
D30, D60, F35,
B300
Wattmetric Ground Fault 1 Function
F60, L60, L90
"
B301
Wattmetric Ground Fault 1 Source
"
B302
Wattmetric Ground Fault 1 Voltage
"
B303
Wattmetric Ground Fault 1 Overvoltage
Pickup
"
B304
Wattmetric Ground Fault 1 Current
"
B305
Wattmetric Ground Fault 1 Overcurrent
Pickup
"
B306
Wattmetric Ground Fault 1 Overcurrent
Pickup Delay
"
B307
Wattmetric Ground Fault 1 Power Pickup
"
B308
Wattmetric Ground Fault 1 ECA
"
B309
Wattmetric Ground Fault 1 Power Pickup
Delay
"
B30A
Wattmetric Ground Fault 1 Curve
"
B30B
Wattmetric Ground Fault 1 Multiplier
"
B30C
Wattmetric Ground Fault 1 Block
"
B30E
Wattmetric Ground Fault 1 Target
"
B30F
Wattmetric Ground Fault 1 Events
"
B310
Wattmetric Ground Fault 1 Reference
Power
"
B311
Wattmetric Ground Fault 1 Reserved
"
B312
...Repeated for Wattmetric Ground Fault 2
F35
B324
...Repeated for Wattmetric Ground Fault 3
"
B336
...Repeated for Wattmetric Ground Fault 4
Wattmetric Ground Fault Actual Values (Read Only) (2 or 4 Modules)
D30, D60, F35,
B360
Wattmetric Ground Fault 1 Operating
F60, L60, L90
Power
"
B362
...Repeated for Wattmetric Ground Fault 2
F35
B364
...Repeated for Wattmetric Ground Fault 3
"
B366
...Repeated for Wattmetric Ground Fault 4
IEC 61850 GGIO1 Configuration Settings (Read/Write Setting)
All
B400
Number of Status Indications in GGIO1
"
B402
IEC 61850 GGIO1 Indication FlexLogic
operands (128 items)
Contact Input Thresholds (Read/Write Setting)
All
B982
Contact Input x Threshold (48 items)
Virtual Inputs (Read/Write Setting) (64 Modules)
All
B9B2
Virtual Input 1 Function
"
B9B3
Virtual Input 1 Name
"
B9BD
Virtual Input 1 Programmed Type
UR FAMILY – COMMUNICATIONS GUIDE
Range
Units
Step
0 to 1
---
1
0 to 1
---
1
0 to 5
---
1
0 to 1
---
1
0.02 to 3
pu
0.01
0 to 1
---
1
0.002 to 30
pu
0.001 F001
0 to 600
s
0.01
0.001 to 1.2
pu
0.001 F001
0 to 360
° Lag
1
0 to 600
s
0.01
0 to 5
---
1
0.01 to 2
s
0.01
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0.001 to 1.2
pu
0.001 F001
0 to 1
---
1
0 to 999999.999
W
0.001 F060
8 to 128
---
8
0 to 4294967295
---
1
0 to 3
---
1
0 to 1
---
1
---
---
---
0 to 1
---
1
MEMORY MAP
Format
Default
F126
0 (No)
F102
0 (Disabled)
F167
0 (SRC 1)
F234
0
(Calculated
VN)
F001
20
F235
0
(Calculated
IN)
60
F001
20
100
F001
0
F001
20
F236
0 (Definite
Time)
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
500
F001
0
0
F001
8
F300
0
F128
2 (84 Vdc)
F102
0 (Disabled)
F636
"Virt Ip 1"
F127
0 (Latched)
2-161
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

D30D60F35F60G30G60 ... Show all