CHAPTER 3: IEC 61850 COMMUNICATION
LNName: Bkr0XCBR#
data obj. data attribute
Type
setSrcRef
ObjectReference SP
VISIBLE
STRING255
setSrcCB
ObjectReference SP
VISIBLE
STRING255
cdcNs
VISIBLE
STRING255
cdcName
VISIBLE
STRING255
InRef6
ORG
GEORG
setSrcRef
ObjectReference SP
VISIBLE
STRING255
setSrcCB
ObjectReference SP
VISIBLE
STRING255
cdcNs
VISIBLE
STRING255
cdcName
VISIBLE
STRING255
InRef7
ORG
GEORG
setSrcRef
ObjectReference SP
VISIBLE
STRING255
setSrcCB
ObjectReference SP
VISIBLE
STRING255
cdcNs
VISIBLE
STRING255
cdcName
VISIBLE
STRING255
InRef8
ORG
GEORG
setSrcRef
ObjectReference SP
VISIBLE
STRING255
setSrcCB
ObjectReference SP
VISIBLE
STRING255
cdcNs
VISIBLE
STRING255
cdcName
VISIBLE
STRING255
UR FAMILY – COMMUNICATIONS GUIDE
LDevice inst: System
UR element: Breaker Control element #
FC UR Name
BREAKER # EXT ALARM
SP
Reference to the ultimate source
of value selected by BREAKER #
EXT ALARM setting
SP
If reference is external to this
IED, mapped to the source's
GOOSE control block, else empty
string
EX
Name of the GE Multilin
namespace at the time of this
firmware release
EX
GEORG
BREAKER # OUT OF SV
SP
Reference to the ultimate source
of value selected by setting
BREAKER # OUT OF SV
SP
If reference is external to this
IED, mapped to the source's
GOOSE control block, else empty
string
EX
Name of the GE Multilin
namespace at the time of this
firmware release
EX
GEORG
XCBR# ST.LOC OPERAND
SP
Reference to the ultimate source
of value selected by setting
XCBR# ST.LOC OPERAND
SP
If reference is external to this
IED, mapped to the source's
GOOSE control block, else empty
string
EX
Name of the GE Multilin
namespace at the time of this
firmware release
EX
GEORG
BREAKER # RACKED-IN
SP
Reference to the ultimate source
of value selected by setting
BREAKER # RACKED-IN
SP
If reference is external to this
IED, mapped to the source's
GOOSE control block, else empty
string
EX
Name of the GE Multilin
namespace at the time of this
firmware release
EX
GEORG
MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Description
reference to the data attribute to input
source GoCB of input if via GOOSE
BREAKER # OUT OF SV (out-of-service)
setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
XCBR# ST.LOC OPERAND (local control)
setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
BREAKER # RACKED-IN setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
R/W/C
R/C
R/C
R/C
R/C
R
R
R
3
R
R/C
R/C
R/C
R/C
R
R
R
R
R/C
R/C
R/C
R/C
R
R
R
R
R/C
R/C
R/C
R/C
R
R
3-153