MEMORY MAP
Products
Address Register name
"
6613
Bus Configuration (Read/Write Setting) (6 Modules)
B90
661E
Thermal Model Actual Values (Read Only)
M60
6630
"
6631
2
"
6633
"
6634
Thermal Model Actuals (Read Only)
M60
6638
"
663A
"
663B
"
663C
"
663D
"
663E
"
663F
Field Ground Actual Values (Read Only)
G60
6640
"
6642
"
6643
"
6644
"
6645
"
6646
"
6648
Accidental Energization (Read/Write Grouped Setting)
G30, G60
6650
"
6651
"
6652
"
6653
"
6655
"
6657
"
6659
"
665B
"
665C
"
665D
Loss of Excitation (Read/Write Grouped Setting)
G30, G60
666A
"
666B
"
666C
"
666D
"
666E
"
666F
"
6670
"
6671
"
6672
2-88
Speed 2 Motor FLA
...Repeated for Bus Zone 2
Thermal Model Motor Status
Thermal Model Capacity Used
Trip Time On Overload
Thermal Model Lockout Time
Thermal Model Load
Thermal Model Motor Unbalance
Thermal Model Biased Motor Load
Start/Hour Lockout Time
Time-Between-Starts Lockout Time
Restart Delay Lockout Time
Total Motor Lockout Time
Field Ground Resistance
Field Ground Current
Field Ground Injected Voltage
Field Ground Fault Location
Field Ground Field Voltage
Field Current
Field Current Units
Accidental Energization Function
Accidental Energization Source
Accidental Energization Arming Mode
Accidental Energization OC Pickup
Accidental Energization UV Pickup
Accidental Energization Offline
Accidental Energization Block
Accidental Energization Target
Accidental Energization Events
Reserved (5 items)
Loss Of Excitation Function
Loss Of Excitation Signal Source
Loss Of Excitation Center 1
Loss Of Excitation Radius 1
Loss Of Excitation UV Supervision Enable 1 0 to 1
Loss Of Excitation Pickup Delay 1
Loss Of Excitation Center 2
Loss Of Excitation Radius 2
Loss Of Excitation UV Supervision Enable 2 0 to 1
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
0.05 to 1
pu
0.001 F001
0 to 3
---
1
0 to 100
%
1
0 to 10000
---
1
0 to 65000
min
1
0 to 40
x FLA
0.01
0 to 100
%
1
0 to 40
x FLA
0.01
0 to 65000
min
1
0 to 65000
min
1
0 to 65000
s
1
0 to 65000
min
1
0 to 20000
kOhm
0.001 F003
0 to 655.35
mA
0.01
-32.767 to 32.767
V
0.001 F002
-30000 to 30000
%
1
-3276.8 to 3276.7
V
0.1
-9999.999 to
---
0.001 F004
9999.999
---
---
---
0 to 1
---
1
0 to 5
---
1
0 to 1
---
1
0.02 to 3
pu
0.001 F003
0.004 to 3
pu
0.001 F003
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 65535
---
1
0 to 1
---
1
0 to 5
---
1
0.1 to 300
ohm
0.01
0.1 to 300
ohm
0.01
---
1
0 to 65.535
s
0.001 F001
0.1 to 300
ohm
0.01
0.1 to 300
ohm
0.01
---
1
UR FAMILY – COMMUNICATIONS GUIDE
Format
Default
1000
F098
1 (Starting)
F001
0
F001
0
F001
0
F001
0
F001
0
F001
0
F001
0
F001
0
F001
0
F001
0
20000000
F001
0
0
F002
-10
F002
0
0
F206
"A"
F102
0 (Disabled)
F167
0 (SRC 1)
F193
0 (UV AND
OFFLINE)
300
500
F300
0
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
F102
0 (Disabled)
F167
0 (SRC 1)
F001
1000
F001
800
F102
1 (Enabled)
50
F001
1200
F001
1000
F102
1 (Enabled)