GE B30 Communications Manual page 94

Ur family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

MEMORY MAP
Products
Address Register name
Ground Time Overcurrent (Read/Write Grouped Setting) (1 or 6 Modules)
B30, C60, C70,
5D00
D30, D60, F35,
F60, G30, G60,
L30, L60, L90,
M60, N60, T35,
T60
2
"
5D01
"
5D02
"
5D03
"
5D04
"
5D05
"
5D06
"
5D07
"
5D09
"
5D0A
"
5D0B
B30, C60, C70,
5D11
D30, D60, F35,
F60, L30, L60,
L90, M60, N60,
T35, T60
"
5D22
"
5D33
"
5D44
"
5D55
Ground Instantaneous Overcurrent (Read/Write Grouped Setting) (1, 6, or 12 Modules)
B30, C60, C70,
5DA0
D30, D60, F35,
F60, G30, G60,
L30, L60, L90,
M60, N60, T35,
T60
"
5DA1
"
5DA2
"
5DA3
"
5DA4
"
5DA5
"
5DA7
"
5DA8
"
5DA9
B30, C60, C70,
5DB1
D30, D60, F35,
F60, L30, L60,
L90, M60, N60,
T35, T60
"
5DC2
2-74
Ground Time Overcurrent 1 Function
Ground Time Overcurrent 1 Signal Source
Ground Time Overcurrent 1 Input
Ground Time Overcurrent 1 Pickup
Ground Time Overcurrent 1 Curve
Ground Time Overcurrent 1 Multiplier
Ground Time Overcurrent 1 Reset
Ground Time Overcurrent 1 Block
Ground Time Overcurrent 1 Target
Ground Time Overcurrent 1 Events
Reserved (6 items)
...Repeated for Ground Time Overcurrent 2
...Repeated for Ground Time Overcurrent 3
...Repeated for Ground Time Overcurrent 4
...Repeated for Ground Time Overcurrent 5
...Repeated for Ground Time Overcurrent 6
Ground Instantaneous Overcurrent 1
Function
Ground Instantaneous Overcurrent 1
Signal Source
Ground Instantaneous Overcurrent 1
Pickup
Ground Instantaneous Overcurrent 1 Delay 0 to 600
Ground Instantaneous Overcurrent 1 Reset
Delay
Ground Instantaneous Overcurrent 1 Block 0 to 4294967295
Ground Instantaneous Overcurrent 1
Target
Ground Instantaneous Overcurrent 1
Events
Reserved (8 items)
...Repeated for Ground Instantaneous
Overcurrent 2
...Repeated for Ground Instantaneous
Overcurrent 3
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
0 to 1
---
1
0 to 5
---
1
0 to 1
---
1
0.02 to 30
pu
0.001 F001
0 to 16
---
1
0 to 600
---
0.01
0 to 1
---
1
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 5
---
1
0.02 to 30
pu
0.001 F001
s
0.01
0 to 600
s
0.01
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
UR FAMILY – COMMUNICATIONS GUIDE
Format
Default
F102
0 (Disabled)
F167
0 (SRC 1)
F122
0 (Phasor)
1000
F103
0 (IEEE Mod
Inv)
F001
100
F104
0
(Instantaneo
us)
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
F102
0 (Disabled)
F167
0 (SRC 1)
1000
F001
0
F001
0
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

D30D60F35F60G30G60 ... Show all

Table of Contents