GE B30 Communications Manual page 112

Ur family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

MEMORY MAP
Products
Address Register name
Reduced Voltage Starting (Read/Write Setting)
M60
6750
"
6751
"
6752
2
"
6753
"
6754
"
6756
"
6757
"
6758
Trip Output (Read/Write Setting)
C60, D60, L60,
6760
L90
"
6761
"
6763
"
6765
"
6767
"
6769
"
676B
"
676D
"
676F
"
6771
"
6773
"
6775
"
6777
"
6779
"
677B
"
677D
"
677F
"
6781
"
6783
"
6785
"
6787
"
6788
"
678A
"
678C
"
678E
"
678F
"
6791
"
6792
"
6793
"
6794
"
6796
"
6798
"
679A
"
679C
2-92
Reduced Voltage Start Function
Reduced Voltage Start Transition Mode
Reduced Voltage Start FLA (full load
current)
Reduced Voltage Start Timer
Reduced Voltage Start Block
Reduced Voltage Target
Reduced Voltage Start Event
Reserved (5 items)
Trip Mode
Trip 3-Pole Input1
Trip 3-Pole Input2
Trip 3-Pole Input3
Trip 3-Pole Input4
Trip 3-Pole Input5
Trip 3-Pole Input6
Trip 1-Pole Input1
Trip 1-Pole Input2
Trip 1-Pole Input3
Trip 1-Pole Input4
Trip 1-Pole Input5
Trip 1-Pole Input6
Trip Reclose Input1
Trip Reclose Input2
Trip Reclose Input3
Trip Reclose Input4
Trip Reclose Input5
Trip Reclose Input6
Trip Force 3-Pole
Trip Pilot Priority
Breaker Phase A Open
Breaker Phase B Open
Breaker Phase C Open
Trip Events
Reverse Fault Operand
Trip Delay On Evolving Faults
Trip Seal-In Delay
Trip Reset
Start Timer Zone 2 Phase Input 1
Start Timer Zone 2 Phase Input 2
Start Timer Zone 2 Ground Input 1
Start Timer Zone 2 Ground Input 2
Phase Selector Reset Delay
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
0 to 1
---
1
0 to 2
---
1
25 to 300
%
1
1 to 600
s
0.1
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 2
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 65.535
s
0.001 F001
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 1
---
1
0 to 4294967295
---
1
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 2
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0.5 to 3
s
0.001 F001
UR FAMILY – COMMUNICATIONS GUIDE
Format
Default
F102
0 (Disabled)
F095
0 (Current
Only)
F001
125
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
F195
0 (Disabled)
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
0
F300
0
F300
0
F300
0
F102
0 (Disabled)
F300
0
0
0
F609
0 (Pole Curr
OR Custom)
F300
0
F300
0
F300
0
F300
0
500

Advertisement

Table of Contents
loading

This manual is also suitable for:

D30D60F35F60G30G60 ... Show all

Table of Contents