GE B30 Communications Manual page 412

Ur family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
LNName: ACsrcMMXU#
data obj. data attribute
phsB.units.SIUnit ENUMERATED
phsB.units
.multiplier
phsB.db
phsB.dbAng
phsB.zeroDb
phsC
phsC.instCVal
phsC.instCVal.mag
.f
phsC.instCVal.ang
.f
phsC.cVal
3
phsC.cVal.mag.f
phsC.cVal.ang.f
phsC.units
phsC.units.SIUnit ENUMERATED
phsC.units
.multiplier
phsC.db
phsC.dbAng
phsC.zeroDb
res
res.instCVal
res.instCVal.mag
.f
res.instCVal.ang
.f
res.cVal
res.cVal.mag.f
res.cVal.ang.f
res.units
res.units.SIUnit
res.units
.multiplier
res.db
res.dbAng
res.zeroDb
angRef
AaRMS
instMag
instMag.f
mag
mag.f
units
units.SIUnit
units.multiplier
db
zeroDb
AbRMS
instMag
instMag.f
3-174
LDevice inst: Meter
UR element: AC Source #
Type
FC UR Name
ENUMERATED
INT32U
CF
MMXU# A.phsB.db
INT32U
CF
MMXU# A.phsB.dbAng
INT32U
CF
CMV
Vector
MX
FLOAT32
SRC # Phase C Current
Magnitude
FLOAT32
SRC # Phase C Current Angle
Vector
MX
FLOAT32
FLOAT32
Unit
CF
ENUMERATED
INT32U
CF
MMXU# A.phsC.db
INT32U
CF
MMXU# A.phsC.dbAng
INT32U
CF
CMV
Vector
MX
FLOAT32
SRC # Neutral Current
Magnitude
FLOAT32
SRC # Neutral Current Angle
Vector
MX
FLOAT32
FLOAT32
Unit
CF
ENUMERATED
ENUMERATED
INT32U
CF
MMXU# A.neut.db
INT32U
CF
MMXU# A.neut.dbAng
INT32U
CF
ENUMERATED
CF
MV
AnalogueValue
MX
FLOAT32
SRC # Phase A Current RMS
AnalogueValue
MX
FLOAT32
Unit
CF
ENUMERATED
ENUMERATED
INT32U
CF
MMXU# RMS A.phsA DEADBAND
INT32U
CF
MV
AnalogueValue
MX
FLOAT32
SRC # Phase B Current RMS
CHAPTER 3: IEC 61850 COMMUNICATION
Description
5, the code for primary amperes
0, the code for a multiplier of 1
current cut-off level.
UR range -180...+180 converted to 0...360 R
instCVal.mag.f deadbanded
instCVal.ang.f deadbanded
5, the code for primary amperes
0, the code for a multiplier of 1
current cut-off level.
UR range -180...+180 converted to 0...360 R
instCVal.mag.f deadbanded
instCVal.ang.f deadbanded
5, the code for primary amperes
0, the code for a multiplier of 1
current cut-off level.
See UR product manual regarding
FREQUENCY AND PHASE REFERENCE
SRC # Phase A Current RMS, in primary
amperes
instMag.f deadbanded
5, the code for primary amperes
0, the code for a multiplier of 1
current cut-off level.
SRC # Phase B Current RMS, in primary
amperes
UR FAMILY – COMMUNICATIONS GUIDE
R/W/C
R
R
R/W/C
R/W/C
R
R
R
R
R
R
R
R
R
R
R/W/C
R/W/C
R
R
R
R
R
R
R
R
R
R
R/W/C
R/W/C
R
R
R
R
R
R
R
R
R
R
R/W/C
R
R
R
R

Advertisement

Table of Contents
loading

This manual is also suitable for:

D30D60F35F60G30G60 ... Show all

Table of Contents