GE B30 Communications Manual page 169

Ur family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

CHAPTER 2: MODBUS COMMUNICATION
Products
Address Register name
"
A28E
Selector 1 Bit Mode
"
A28F
Selector 1 Bit Acknowledge
"
A291
Selector 1 Power Up Mode
"
A292
Selector 1 Target
"
A293
Selector 1 Events
"
A294
Reserved (10 items)
"
A29E
...Repeated for Selector 2
Expanded B90 Direct Input/Output Status (Read Only)
B90
A300
Direct Device States, one per register (16
items)
"
A310
Direct Input States, one per register (256
items)
Digital Counter (Read/Write Setting) (8 Modules)
All except B90
A300
Digital Counter 1 Function
"
A301
Digital Counter 1 Name
"
A307
Digital Counter 1 Units
"
A30A
Digital Counter 1 Block
"
A30C
Digital Counter 1 Up
"
A30E
Digital Counter 1 Down
"
A311
Digital Counter 1 Preset
"
A313
Digital Counter 1 Compare
"
A315
Digital Counter 1 Reset
"
A317
Digital Counter 1 Freeze/Reset
"
A319
Digital Counter 1 Freeze/Count
"
A31B
Digital Counter 1 Set To Preset
"
A31D
Reserved (11 items)
"
A328
...Repeated for Digital Counter 2
"
A350
...Repeated for Digital Counter 3
"
A378
...Repeated for Digital Counter 4
"
A3A0
...Repeated for Digital Counter 5
"
A3C8
...Repeated for Digital Counter 6
"
A3F0
...Repeated for Digital Counter 7
"
A418
...Repeated for Digital Counter 8
PID Regulator (Read/Write Setting) (4 Modules)
C30, F35
A500
PID 1 Function
"
A501
PID 1 Sample Time
"
A502
PID 1 Process Signal
"
A503
PID 1 Setpoint Signal
"
A505
PID 1 Tracking Signal
"
A506
PID 1 Proportional Gain
"
A507
PID 1 Setpoint Weighting
"
A508
PID 1 Integ Time Const
"
A509
PID 1 Antiwindup
"
A50A
PID 1 AW Time Const
"
A50B
PID 1 Deriv Time Const
UR FAMILY – COMMUNICATIONS GUIDE
Range
Units
Step
0 to 1
---
1
0 to 4294967295
---
1
0 to 2
---
1
0 to 2
---
1
0 to 1
---
1
---
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
---
---
---
---
---
---
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
–2147483647 to
---
1
2147483647
–2147483647 to
---
1
2147483647
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
---
---
---
0 to 1
---
1
0.05 to 30
sec
0.01
0 to 65535
---
1
-99999.99 to
---
0.01
99999.99
0 to 65535
---
1
0.01 to 100
---
0.01
0.01 to 1
---
0.01
0 to 600
sec
0.01
0 to 1
---
1
0 to 600
sec
0.01
0 to 600
sec
0.01
MEMORY MAP
Format
Default
F083
0 (Time-out)
F300
0
F084
0 (Restore)
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
F155
0 (Offline)
F108
0 (Off)
F102
0 (Disabled)
F205
"Counter 1"
F206
(none)
F300
0
F300
0
F300
0
F004
0
F004
0
F300
0
F300
0
F300
0
F300
0
F001
0
F102
0 (Disabled)
F001
5
F600
0
F004
0
F600
0
F001
100
F001
100
F001
100
F102
0 (Disabled)
F001
100
F001
100