MEMORY MAP
Products
Address Register name
Capacitor Bank Overvoltage Actuals (Read Only) (3 Modules)
C70
6390
"
6391
"
6392
2
"
6393
"
6396
Negative Sequence Instantaneous Overcurrent (Read/Write Grouped Setting) (2 or 3 Modules)
C70, D30, D60,
63C0
F35, F60, L30,
L60, L90, T60
"
63C1
"
63C2
"
63C3
"
63C4
"
63C5
"
63C7
"
63C8
"
63C9
"
63D1
T60
63E2
Current Unbalance (Read/Write Grouped Setting) (2 Modules)
M60
6400
"
6401
"
6402
"
6403
"
6404
"
6406
"
6407
"
6408
"
640D
Stator Differential (Read/Write Grouped Setting)
G60, M60
6420
"
6421
"
6422
"
6423
"
6424
"
6425
"
6426
"
6428
2-84
Bank Overvoltage 1 Phase A Operate
Voltage
Bank Overvoltage 1 Phase B Operate
Voltage
Bank Overvoltage 1 Phase C Operate
Voltage
...Repeated for Bank Overvoltage 2
...Repeated for Bank Overvoltage 3
Negative Sequence Instantaneous OC 1
Function
Negative Sequence Instantaneous OC 1
Signal Source
Negative Sequence Instantaneous
Overcurrent 1 Pickup
Negative Sequence Instantaneous
Overcurrent 1 Delay
Negative Sequence Instantaneous OC 1
Reset Delay
Negative Sequence Instantaneous
Overcurrent 1 Block
Negative Sequence Instantaneous
Overcurrent 1 Target
Negative Sequence Instantaneous
Overcurrent 1 Events
Reserved (8 items)
...Repeated for Negative Sequence
Instantaneous OC 2
...Repeated for Negative Sequence
Instantaneous OC 3
Current Unbalance 1 Function
Current Unbalance 1 Pickup
Current Unbalance 1 Pickup Delay
Current Unbalance 1 Reset Delay
Current Unbalance 1 Block
Current Unbalance 1 Targets
Current Unbalance 1 Events
Current Unbalance 1 Reserved (5 items)
...Repeated for Current Unbalance 2
Stator Differential Function
Stator Differential Pickup
Stator Differential Slope 1
Stator Differential Slope 2
Stator Differential Break 1
Stator Differential Break 2
Stator Differential Block
Stator Differential Targets
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
0 to 65.535
pu
0.001 F001
0 to 65.535
pu
0.001 F001
0 to 65.535
pu
0.001 F001
0 to 1
---
1
0 to 5
---
1
0.02 to 30
pu
0.001 F001
0 to 600
s
0.01
0 to 600
s
0.01
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0.1 to 100
%
0.1
0 to 600
s
0.01
0 to 600
s
0.01
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0.05 to 1
pu
0.001 F001
1 to 100
%
1
1 to 100
%
1
1 to 1.5
pu
0.01
1.5 to 30
pu
0.01
0 to 4294967295
---
1
0 to 2
---
1
UR FAMILY – COMMUNICATIONS GUIDE
Format
Default
0
0
0
F102
0 (Disabled)
F167
0 (SRC 1)
1000
F001
0
F001
0
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
F102
0 (Disabled)
F001
400
F001
0
F001
0
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
F102
0 (Disabled)
100
F001
10
F001
80
F001
115
F001
800
F300
0
F109
0 (Self-reset)