CHAPTER 2: MODBUS COMMUNICATION
Products
Address Register name
"
6673
Loss Of Excitation Pickup Delay 2
"
6674
Loss Of Excitation UV Supervision
"
6675
Loss Of Excitation Block
"
6677
Loss Of Excitation Target
"
6678
Loss Of Excitation Events
"
6679
Reserved (5 items)
Bus Configuration (Read/Write Setting) (6 Modules)
B90
667E
...Repeated for Bus Zone 3
Sensitive Directional Power (Read/Write Grouped Setting) (2 Modules)
C60, D60, F60,
6680
Sensitive Directional Power 1 Function
G30, G60, L90,
M60, N60, T60
"
6681
Sensitive Directional Power 1 Signal Source 0 to 5
"
6682
Sensitive Directional Power 1 RCA
"
6683
Sensitive Directional Power 1 Calibration
"
6684
Sensitive Directional Power 1 STG1 SMIN
"
6685
Sensitive Directional Power 1 STG1 Delay
"
6686
Sensitive Directional Power 1 STG2 SMIN
"
6687
Sensitive Directional Power 1 STG2 Delay
"
6688
Sensitive Directional Power 1 Block
"
668A
Sensitive Directional Power 1 Target
"
668B
Sensitive Directional Power 1 Events
"
668C
Reserved (5 items)
"
6691
...Repeated for Sensitive Directional Power
2
Underpower (Read/Write Grouped Setting) (2 Modules)
M60
66AA
Underpower 1 Function
"
66AB
Underpower 1 Start Block Delay
"
66AC
Underpower 1 Alarm Power Pickup
"
66AD
Underpower 1 Alarm Pickup Delay
"
66AE
Underpower 1 Trip Power Pickup
Underpower (Read/Write Grouped Setting) (2 Modules)
M60
66AF
Underpower 1 Trip Pickup Delay
"
66B0
Underpower 1 Trip Reset Delay
"
66B1
Underpower 1 Block
"
66B3
Underpower 1 Target
"
66B4
Underpower 1 Events
"
66B5
...Repeated for Underpower 2
Load Encroachment (Read/Write Grouped Setting)
D30, D60, F60,
66C0
Load Encroachment Function
L60, L90, T60
"
66C1
Load Encroachment Source
"
66C2
Load Encroachment Minimum Voltage
"
66C3
Load Encroachment Reach
"
66C4
Load Encroachment Angle
"
66C5
Load Encroachment Pickup Delay
"
66C6
Load Encroachment Reset Delay
"
66C7
Load Encroachment Block
UR FAMILY – COMMUNICATIONS GUIDE
Range
Units
Step
0 to 65.535
s
0.001 F001
0 to 1.25
pu
0.001 F001
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 65535
---
1
0 to 1
---
1
---
1
0 to 359
degrees 1
0 to 0.95
degrees 0.05
-1.2 to 1.2
pu
0.001 F002
0 to 600
s
0.01
-1.2 to 1.2
pu
0.001 F002
0 to 600
s
0.01
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 65535
---
1
0 to 1
---
1
0 to 600
s
0.01
0.05 to 2
pu
0.01
0 to 600
s
0.01
0.05 to 2
pu
0.01
0 to 600
s
0.01
0 to 600
s
0.01
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 5
---
1
0.004 to 3
pu
0.001 F001
0.02 to 250
ohms
0.01
5 to 50
degrees 1
0 to 65.535
s
0.001 F001
0 to 65.535
s
0.001 F001
0 to 4294967295
---
1
MEMORY MAP
Format
Default
500
700
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
F102
0 (Disabled)
F167
0 (SRC 1)
F001
0
F001
0
100
F001
50
100
F001
2000
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
F102
0 (Disabled)
F001
50
F001
50
F001
200
F001
40
F001
100
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F102
0 (Disabled)
F167
0 (SRC 1)
250
F001
100
F001
30
0
0
F300
0