About Afids; Configuring Default Afids - Cisco AP776A - Nexus Converged Network Switch 5020 Configuration Manual

Cisco mds 9000 family cli configuration guide - release 4.x (ol-18084-01, february 2009)
Hide thumbs Also See for AP776A - Nexus Converged Network Switch 5020:
Table of Contents

Advertisement

Configuring IVR
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
1
2
Total:
Use the show ivr service-group configured command to view the configured IVR service group
database.
switch# show ivr service-group configured
IVR CONFIGURED Service Group
====================================
SG-ID
------------------------------------------------------------------------------
1
1
2
Total:

About AFIDs

You can configure AFIDs individually for VSANs, or you can set the default AFIDs for all VSANs on
a switch. If you configure an individual AFID for a subset of the VSANs on a switch that has a default
AFID, that subset uses the configured AFID while all other VSANs on that switch use the default AFID.
IVR supports a maximum of 64 AFIDs.
You can only use AFID configuration when the VSAN topology mode is automatic. In user-configured
Note
VSAN topology mode, the AFIDs are specified in the VSAN topology configuration itself and a separate
AFID configuration is not needed.

Configuring Default AFIDs

To configure the default AFID, follow these steps:
Command
Step 1
switch# config t
switch(config)#
Step 2
switch(config)# autonomous-fabric-id database
Step 3
switch(config-afid-db)# switch-wwn
20:00:00:0c:91:90:3e:80
default-autonomous-fabric-id 5
switch(config-afid-db)# no switch-wwn
20:00:00:0c:91:90:3e:80
default-autonomous-fabric-id 5
Cisco MDS 9000 Family CLI Configuration Guide
23-16
IVR-SG1
11
1
IVR-SG2
20
3-5
3 entries in active service group table
SG-NAME
AFID
VSANS
IVR-SG1
10
1-2,6-10
IVR-SG1
11
1
IVR-SG2
20
3-5
3 entries in configured service group table
Chapter 23
Configuring Inter-VSAN Routing
Purpose
Enters configuration mode.
Enters AFID database configuration submode.
Configures the default AFID for all VSANs not
explicitly associated with an AFID. The valid
range for the default AFID is 1 to 64.
Reverts to the default value (1) for the default
AFID.
OL-18084-01, Cisco MDS NX-OS Release 4.x

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents