Power Supply Configuration Modes
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Table 11-1
Scenario
1
2
3
1. W = Watts
Table 11-2
Scenario
1
2
3
1. W = Watts
2.
Cisco MDS 9000 Family CLI Configuration Guide
11-12
Redundant Mode Power Supply Scenarios
Power
Current
Supply 1
Usage
1
(W)
(W)
2500
2000
2500
2000
2500
2000
Combined mode—The total power is twice the lesser of the two power supply capacities.
b.
For example, suppose you have the following usage figures configured:
Power supply 1 = 2500 W
Additional Power supply 2 = not used
Current Usage = 2000 W
Current capacity = 2500 W
Then the following three scenarios will differ as specified (see
Scenario 1: If 1800 W is added as power supply 2, then the capacity increases to 3600 W.
Reason: 3600 W is twice the minimum (1800 W).
Scenario 2: If 2200 W is added as power supply 2, then the current capacity increases to
4400 W.
Reason: 4400 W is twice the minimum (2200 W).
Scenario 3: If 3000 W is added as power supply 2, then the current capacity increases to
5000 W.
Reason: 5000 W is twice the minimum (2500 W).
Combined Mode Power Supply Scenarios
Power
Current
Supply 1
Usage
1
(W)
(W)
2500
2000
2500
2000
2500
2000
When you change the configuration from combined to redundant mode and the system detects a
power supply that has a capacity lower than the current usage, the power supply is shut down. If both
power supplies have a lower capacity than the current system usage, the configuration is not allowed.
Several configuration scenarios are summarized in
Scenario 1: You have the following usage figures configured:
Power supply 1 = 2500 W
Additional Power supply 2 = 1800 W
Current Usage = 2000 W
Current mode = combined mode (so current capacity is 3600 W)
Insertion of
New
Power
Capacity
Supply 2 (W)
(W)
1800
2500
2200
2200
3300
2500
Insertion of
New
Power
Capacity
Supply 2 (W)
(W)
1800
3600
2200
4400
3300
5000
Table
11-3.
Chapter 11
Managing System Hardware
Action Taken by Switch
Power supply 2 is shut down.
Capacity becomes 2200 W.
Capacity remains the same.
Table
11-2):
Action Taken by Switch
Power is never shut down. The
new capacity is changed.
OL-18084-01, Cisco MDS NX-OS Release 4.x