event

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
entry-op op
exit-val value
exit-op op
fanabsent
fan number
time seconds
fanbad
memory
critical
minor
severe
module-failure
type
failure-type
module slot | all
oir
fan
module
powersupply
anyoir | insert | remove Specify the OIR event that triggers the EEM applet.
number
policy-default
poweroverbudget
snmp
oid oid
Cisco MDS 9000 Family Command Reference
7-10
(Optional) Compares the contents of the current counter with the exit value
using a specified operator:
•eq—Equal to
•ge—Greater than or equal to
•gt—Greater than
•le—Less than or equal to
•lt—Less than
•ne—Not equal to
(Optional) Specifies the value with which the contents of the current
counter are compared to decide whether the exit criteria are met.The exit
value ranges from 0 to 2147483647.
Specifies fanabsent event specification.
The fan number range is from 1 to 4.
The seconds range is from 0 to 4294967295.
Specifes fanbad event specification.
Specifies the memory thresholds event specification.
Specifies critical alert.
Specifies minor alert.
Specifies severe alert.
Specifies a module failure event specification.
Specifies the type of failure condition.
Specifies that one module or all modules must be monitored.
Specifies online-insertion-removal event specification.
Specifies the system fans. Optionally specifies an individual fan.
Specifies the system modules. Optionally specifies an individual module.
Specifies the system power supplies. Optionally specifies an individual
power supply.
•insert—OIR insert
•remove—OIR remove
•anyoir—Either OIR insert or OIR remove
(Optional) If you selected fan, enter a fan number to monitor for an OIR
event. The number is in the range of 1-4. If you selected module, enter a
module number to monitor for an OIR event. The number is in the range of
1-10. If you selected powersupply, enter a power supply number to monitor
for an OIR event. The number is in the range of 1-3.
Specifies the event in the system policy being overridden.
Specifies poweroverbudget event specification.
Specifies a SNMP event specification.
Specifies the OID of data element in dot notation.
Chapter 7
E Commands
OL-18089-01, Cisco MDS NX-OS Release 4.x