rmon alarm

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Examples
The following example configures a 32-bit alarm number 20 for ifInErrors (OID 1.3.6.1.2.1.2.2.1.14)
on interface fc 1/1. The sample interval is 30 seconds and delta samples are tested. The rising threshold
is 15 errors per sample window; reaching this level triggers event 1. The falling threshold is 0 errors in
the sample window which triggers event 0 (no action). The owner is 'ifInErrors.fc1/1@test'.
switch# config terminal
switch(config)# rmon alarm 20 1.3.6.1.2.1.2.2.1.14.16777216 30 delta rising-threshold 15
1 falling-threshold 0 owner ifInErrors.fc1/1@test
Related Commands
Command
rmon event
rmon hcalarm
show rmon
show snmp host
snmp-server host
Cisco MDS 9000 Family Command Reference
20-26
Description
Configures an RMON event.
Configures the 64-bit RMON alarm.
Displays RMON configuration and logging information.
Displays the SNMP trap destination information.
Specifies the recipient of an SNMP notification.