System Upgrades; Firmware Upgrade (Package Installation) - Cisco SCE2020-4XGBE-SM Configuration Manual

Software configuration guide
Table of Contents

Advertisement

System Upgrades

System Upgrades
In a redundant solution, it is important that firmware and/or application upgrades be performed in such
a way that line and service are preserved.
Refer to the following sections for instructions on how to perform these procedures on two cascaded SCE
platforms:
When upgrading only one component (either firmware only or application only), always verify that the
Note
upgraded component is compatible with the component that was not upgraded.

Firmware Upgrade (package installation)

Install package on both SCE platforms (open the package and copy configuration).
Step 1
Reload the standby SCE platform.
Step 2
Wait until the standby finishes synchronizing and is ready to work.
Step 3
Make sure that the connection mode configurations are correct.
Step 4
Reload the active SCE platform.
Step 5
After the former active SCE platform reboots and is ready to work manually, it may be left as standby
Step 6
or we can manually switch the SCE platforms to their original state.
Cisco SCE 2000 and SCE 1000 Software Configuration Guide
10-12
Firmware Upgrade (package installation), page 10-12
Application Upgrade, page 10-13
Simultaneous Upgrade of Firmware and Application, page 10-13
Upgrade the firmware only
Upgrade the application only
Upgrade both the firmware and the application at the same time
Chapter 10
Redundancy and Fail-Over
OL-7827-12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sce 2000Sce 1000

Table of Contents