Cisco SCE2020-4XGBE-SM Configuration Manual page 81

Software configuration guide
Table of Contents

Advertisement

Chapter 4
Utilities
Table 4-1
Parameter
SNMP agent status
GET community names
SET community names
trap managers (maximum 20)
Authentication Failure trap
status
enterprise traps status
system administrator
Topology Configuration (All Platforms)
connection mode
Admin status of the SCE
platform after abnormal boot
Topology Configuration (SCE 1000)
link bypass mode on operational
status
redundant SCE 1000 platform?
link bypass mode on
non-operational status
Topology Configuration (SCE 2000)
type of deployment
physically connected link
(cascade topology only)
priority (cascade topology only) If this is a cascaded topology, is this SCE 2000 the primary or
on-failure behavior (inline
connection mode only)
Information regarding these parameters can be found in the appropriate sections throughout this guide.
For more information regarding SCE platform topology, and for a step-by-step description of the setup
utility, see the Cisco SCE 2000/SCE 1000 Installation and Configuration Guides.
OL-7827-12
Setup Command Parameters (continued)
Definition
SNMP agent status Enable or disable SNMP management.
Community strings to allow GET access and associated ACLs
(maximum 20).
Community strings to allow SET access and associated ACLs
(maximum 20).
Trap manager IP address, community string, and SNMP version.
Sets the status of the Authentication Failure traps.
Sets the status of the enterprise traps.
Name of the system administrator.
Is the SCE platform installed in bump-in-the-wire topology (inline)
or out of line using an optical splitter or external switch
(receive-only)?
After a reboot due to a failure, should the SCE platform remain in a
Failure status or move to operational status provided no other
problem was detected?
When the SCE 1000 is operational, should it bypass traffic or not?
Is there a redundant SCE 1000 installed as a backup?
When the SCE 1000 is not operational, should it bypass traffic or
cut it off?
Is this a cascade topology, with two SCE platforms connected via
the cascade ports? Or is this a single platform topology?
In a cascade deployment this parameter sets the index for the link
that this SCE 2000 is deployed on. The options for the SCE 2000
are link-0 or link-1.
In a single-SCE 2000 Platform deployment this parameter is not
relevant since one SCE 2000 is deployed on both links. In this case
the link connected to port1-port2 is by default link-0 and the link
connected to port3-port4 is by default link-1.
secondary SCE 2000?
If this SCE 2000 is deployed inline, should the failure behavior be
bypass or cutoff of the link?
Cisco SCE 2000 and SCE 1000 Software Configuration Guide
The Setup Command
4-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sce 2000Sce 1000

Table of Contents