Cisco SCE 1000 2xGBE
Installation and Configuration Guide
Version 3.0
OL-7821-04
Corporate Headquarters
C isco Sys te ms , Inc .
1 70 W es t Tas ma n D r i ve
Sa n Jose , C A 9 513 4-1 706
U S A
h t t p : / /w w w .c i s c o .co m
T e l:
4 08 5 26- 400 0
8 00 5 53-NET S ( 638 7)
F a x :
4 08 5 26- 410 0
Customer Order Number: DOC7821-04=
Text Part Number: OL-7821-04

Advertisement

Table of Contents
loading

Summary of Contents for Cisco SCE 1000

  • Page 1 Cisco SCE 1000 2xGBE Installation and Configuration Guide Version 3.0 OL-7821-04 Corporate Headquarters C isco Sys te ms , Inc . 1 70 W es t Tas ma n D r i ve Sa n Jose , C A 9 513 4-1 706 U S A h t t p : / /w w w .c i s c o .co m...
  • Page 2 You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures: •...
  • Page 3: Table Of Contents

    The SCE Platform 1-3 Management and Collection 1-5 Network Management 1-5 Subscriber Management 1-6 Collection 1-6 Service Configuration Management 1-6 Introduction to the SCE Platform 2-1 The SCE Platform 2-1 Front Panel 2-2 Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 4 Tools and Parts Required 4-2 Site Requirement Guidelines 4-3 Installing the SCE 1000 Platform 4-4 Installation Precautions 4-5 Installing the SCE 1000 on a Workbench or Tabletop 4-5 Rack-Mounting a SCE 1000 Platform 4-6 Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 5 Connecting the Management Interface 5-23 Cabling the Management Port 5-23 Verifying Management Interface Connectivity 5-24 Cabling the Line Ports and Completing the Installation 6-1 Connecting the line ports to the network 6-1 Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 6 Troubleshooting the Power Subsystem 8-9 Troubleshooting the Firmware Package Installation 8-11 Troubleshooting the Management Subsystem 8-12 Troubleshooting the Link Interface Subsystem 8-14 The External Optical Bypass Module A-1 External Optical Bypass Functionality A-2 Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 7 The External Optical Bypass Module Front Panel A-3 Installing the External Bypass Module A-3 Installing the Module in a Rack A-4 Cabling the External Optical Bypass Module A-4 Specifications A-6 Index I-1 Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 9: Preface

    This guide contains instructions on how to install and run the SCE 1000 platform. This guide assumes a basic familiarity with telecommunications equipment and installation procedures. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 10: Organization

    The major sections of this guide are as follows: Chapter Title Description Chapter 1 Introduction This chapter provides a brief introduction to Cisco Service Control. Chapter 2 Overview ("Introduction This chapter provides a hardware overview of the SCE to the SCE Platform"...
  • Page 11: Related Publications

    Cisco Service Control Management Suite Collection Manager User Guide Cisco Service Control Application for Broadband User Guide • Cisco Service Control Application Reporter User Guide • To view Cisco documentation or obtain general information about the documentation, refer to • the following sources: • Obtaining Documentation on page The Cisco Information Packet that shipped with your SCE 1000 platform.
  • Page 12: Conventions

    Means reader take note. Notes contain helpful suggestions or references to materials not contained in this manual. Cautions use the following conventions: Means reader be careful. You are capable of doing something that might result in equipment damage or Caution loss of data. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 13: Obtaining Documentation

    Means reader be warned. You are capable of doing something that might result in bodily injury. Obtaining Documentation The following sections provide sources for obtaining documentation from Cisco Systems. World Wide Web You can access the most current Cisco documentation on the World Wide Web at the following sites: http://www.cisco.com •...
  • Page 14: Documentation Feedback

    Obtaining Technical Assistance Documentation Feedback If you are reading Cisco product documentation on the World Wide Web, you can submit technical comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco.
  • Page 15: Technical Assistance Center

    P4—You need information or assistance on Cisco product capabilities, product installation, or • basic product configuration. In each of the above cases, use the Cisco TAC website to quickly find answers to your questions. To register for Cisco.com (on page xii), go to the following website: http://tools.cisco.com/RPF/register/register.do...
  • Page 17: Overview

    C H A P T E R 1 Overview This chapter provides a general overview of the Cisco Service Control solution. It introduces the Cisco Service Control concept and the Service Control capabilities. It also briefly describes the hardware capabilities of the Service Control Engine (SCE) platform, as well as the Cisco specific applications that together compose the total Cisco Service Control solution.
  • Page 18: Service Control For Broadband Service Providers

    IP services. The Cisco Service Control Application for Broadband adds a new layer of service intelligence and control to existing networks that can: Report and analyze network traffic at subscriber and aggregate level for capacity planning •...
  • Page 19: The Sce Platform

    Streaming & Multimedia—RTSP, SIP, HTTP streaming, RTP/RTCP, and others Programmable system core for flexible reporting and bandwidth control • Transparent network and BSS/OSS integration into existing networks • Subscriber awareness that relates traffic and usage to specific customers • Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 20 Chapter 1 Overview The SCE Platform The following diagram illustrates a common deployment of an SCE platform in a network. Figure 1-1: SCE Platform in the Network Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 21: Management And Collection

    Chapter 1 Overview Management and Collection Management and Collection The Cisco Service Control solution includes a complete management infrastructure that provides the following management components to manage all aspects of the solution: • Network management Subscriber management • Service Control management •...
  • Page 22: Subscriber Management

    Pull Mode—On-demand, in response to a query from the SCE platform to the SM Collection The Cisco Service Control solution generates usage data and statistics from the SCE platform and forwards them as Raw Data Records (RDRs), using a simple TCP-based protocol (RDR- Protocol).
  • Page 23: Introduction To The Sce Platform

    SCE 1000 Installation Checklist The SCE Platform The Service Control Engine (SCE) platform, which is the hardware component of the Cisco Service Control solution, is designed to support observation, analysis, and control of Internet/IP traffic. The following table summarizes model information for the SCE 1000 platform...
  • Page 24: Front Panel

    Refer to Connecting the Line to the link. Ports ("Connecting the line ports to the network" on page CLI designation: interface 6-1) for cabling diagrams for GigabitEthernet 0/1 and 0/2 various topologies Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 25 Unlit — indicates that the port link is down • Rx Flashing Green — indicates that there are incoming packets • Tx Flashing Green — indicates that there are outgoing packets Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 26: Back Panel

    The rear panels of both the AC- and DC-powered SCE 1000 platforms are shown in the following pair of figures. Figure 2-2: SCE 1000 Back Panel: AC Power Figure 2-3: SCE 1000 Back Panel DC power Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 27: Checking The Shipping Container Contents

    • 1 19" rack mounting panel • 1 control cable *Titles and quantities of documents will vary. You must order the type and quantity of documentation sets when you order the hardware. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 28 If you ordered documentation and did not receive it, we will ship the documents to you within 24 hours. To order documents, contact a customer service representative. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 29: Sce 1000 Installation Checklist

    FE management port is operational GBE line ports operational Network interface cables and devices connected System power turned on System boot complete (SYSTEM–UP LED is on) Correct hardware configuration displayed after system banner appears Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 31: Topology

    C H A P T E R 3 Topology This chapter describes the possible deployment topologies of the SCE 1000. The Cisco SCE solution offers a number of basic topology options that permit the user to tailor the SCE Platform to fit the needs of a particular installation.
  • Page 32: Sce Platform Configuration

    "receive-only"-like monitoring functions, when control functionality is not required. The bypass card supports the following four modes: Bypass — The bypass mechanism preserves the network link, but traffic is not processed for • monitoring or for control. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 33: Functionality

    There are two options for the physical installation configuration of the SCE 1000 Platform: Inline installation (provides control functionality). • Out-of-line installation utilizing an external optical splitte • The physical installation determines the connection mode that should be configured. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 34: Bump-In-The-Wire (Inline) Topology

    SCE 1000. The external splitter is connected to the SCE 1000 via Rx links only. The SCE 1000, therefore, receives traffic only. It does not transmit. Figure 3-2: External Splitting Topology Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 35: Redundancy

    (as is the case when HSRP with two virtual routers is used), if one link fails, its traffic is directed to the other link. However, the overall supported load in the link that is now carrying all the traffic is only equal to one link, not two. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 36: Failure And Recovery

    SCE 1000 platforms are in the same Domain. All configurations performed on this Domain are automatically updated on both SCE Platforms. Both boxes should also be assigned to the same Subscriber Domain. For more information on Domains, see the Cisco SCMS Subscriber Manager User Guide.
  • Page 37: Maintaining The Network Links Vs Maintaining Sce 1000 Platform Functionality

    Receive-only — The SCE 1000 does not reside physically on the data link. Data is forwarded • to the SCE 1000 via an external optical splitter. The SCE 1000 itself receives only and does not transmit. Default value = Inline Note Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 38: On-Failure Mode Parameter

    No link failure-reflection — Link failure is not reflected to the other port. • Default value = no link failure-reflection Note Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 39: Status Of The Sce 1000 After Abnormal Boot

    [1]: In a redundant topology, it is also possible to configure admin status after abnormal boot to be Not operational. In this case, though, the SCE 1000 would have to be manually reloaded in order to resume full functionality. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 41: Installation And Maintenance

    Before you install, operate, or service the system, read the Regulatory Compliance and Safety Warning Information for the Cisco Service Control Engine. This guide contains important safety information you should know before working with the system. This chapter contains the following sections: •...
  • Page 42: Tools And Parts Required

    Appropriate cables to connect the SCE 1000 to the network and console terminal • Rack-mounting kit (optional) • A new AC-input or DC-input power supply • A new fan module • Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 43: Site Requirement Guidelines

    Specification Acceptable Range Temperature - nominal 41°F to 104°F (5°C to 40°C) Short term temperatures* 23°F to 131°F (-5°C to +55°C) Relative humidity 5% to 95% (non-condensing) Heat dissipation 683 BTU/hour Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 44: Installing The Sce 1000 Platform

    019,IEC/EN60825-1, -2, 21CFR1040, 73/23/ECC For more complete information regarding safety and regulatory compliance, refer to the Regulatory Compliance and Safety Information for the Cisco Service Control Engine document. The DC-powered SCE 1000 should be installed in a Restricted Access Location only.
  • Page 45: Installation Precautions

    Remove any debris and dust from the tabletop or workbench, as well as the surrounding area. Also make sure your path between the SCE 1000 platform and its new location is unobstructed. Place the SCE 1000 platform on the tabletop or workbench. Step 2 Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 46: Rack-Mounting A Sce 1000 Platform

    Because the inlet and exhaust ports (vents) for cooling air are located at both sides of the chassis, respectively, multiple SCE 1000s can be stacked in a rack with no vertical clearance. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 47: Attaching The Brackets To The Sce

    "Mounting the System to the Rack" on page 4-9). If mounting the SCE 1000 in a rack with four posts, proceed to the next step to attach the crossrail supports to the rack. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 48: Attaching The Crossrail Supports To The Rack

    The SCE 1000 then slides into these crossrails, which support the weight of the unit. Cisco recommends that you allow at least 1 or 2 inches (2.54 or 5.08 cm) of vertical clearance between Note the SCE 1000 and any equipment directly above and below it.
  • Page 49: Mounting The System To The Rack

    A rack with both front and back posts will have the crossrail supports installed. Slide the SCE 1000 onto these crossrails and push it all the way back. Figure 4-8: Sliding the SCE 1000 into the Rack Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 50: Attaching A Chassis Ground Connection

    On the Rear panel of the SCE 1000, locate the chassis grounding connector (refer to the Step 2 appropriate figure for an AC- or DC-powered SCE 1000 below). Cisco SCE 1000 2xGBE Installation and Configuration Guide 4-10 OL-7821-04...
  • Page 51: Power Supply Overview

    Dual line feed AC power — SCE 1000 is shipped with two appropriate AC power supply • cords. • Dual line feed DC power — requires appropriate cables (hex or loop connectors) (see Connecting the DC Power Supply). Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 4-11...
  • Page 52: Leds

    (on page 2-2): • Power LED — There are two Power LEDs on the front panel (Power A and Power B), one • LED corresponding to each power supply unit Cisco SCE 1000 2xGBE Installation and Configuration Guide 4-12 OL-7821-04...
  • Page 53 Simple Network Management Protocol (SNMP) monitors the activity of the power supplies. In most cases when a power supply problem occurs, an SNMP trap is sent in SNMP and the appropriate message is posted on the SCE 1000 CLI. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 4-13...
  • Page 54: Power Supply Specifications

    Attach the copper tape strap to an unpainted metal surface on the chassis. You may leave the strap connected to the chassis when your have finished. Cisco SCE 1000 2xGBE Installation and Configuration Guide 4-14...
  • Page 55: Powering Down The Power Supply Unit And Disconnecting Input Power

    Remove the cable from the AC-input power receptacle This completes the procedure for powering down an AC-input power supply unit on a SCE 1000 platform. Proceed to Removing the Power Supply Unit (on page 4-16). Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 4-15...
  • Page 56: Removing The Power Supply Unit

    Step 2 Grasp the power supply handle and pull the power supply from the router. This completes the procedure for removing the power supply from a SCE 1000 platform. Cisco SCE 1000 2xGBE Installation and Configuration Guide 4-16 OL-7821-04...
  • Page 57: Replacing The Power Supply Unit

    The following sections describe how to reconnect the AC or DC power: Reconnecting AC-Input Power Supply Unit (on page 4-18) • • Reconnecting DC-Input Power Supply Unit (on page 4-18) Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 4-17...
  • Page 58: Reconnecting Ac-Input Power Supply Unit

    Note that the power to the relevant power supply unit should be off, not necessarily all power to the SCE 1000 platform. One DC-input power supply can be running when the other power supply is being removed or replaced. Cisco SCE 1000 2xGBE Installation and Configuration Guide 4-18 OL-7821-04...
  • Page 59 Look at the IN and OK LEDs on the power supply unit and the corresponding Power LED on the front panel. If the new DC-input power supply unit is operating properly, these LEDs will be glowing green. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 4-19...
  • Page 60: Fan Module Overview

    Removing the Fan Module When removing the fan drawer, keep hands and fingers away from the spinning fan blades. Let the fan Warning blades stop completely before removing the fan drawer. Cisco SCE 1000 2xGBE Installation and Configuration Guide 4-20 OL-7821-04...
  • Page 61: Replacing The Fan Module

    The fan module is not fully seated until you tighten the installation screws on the faceplate. Note This completes the procedures for replacing a fan module in a SCE 1000 platform. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 4-21...
  • Page 62: Replacing The Battery

    Replacing the Battery Replacing the Battery The SCE 1000 has a lithium battery on its main circuit board. When the battery loses its charge, call Cisco Technical Support to replace the battery. Do not attempt to replace this battery yourself Warning There is danger of explosion if the lithium battery is incorrectly replaced.
  • Page 63: Connecting The Management Interfaces And Performing Initial System Configuration

    SCE 1000 to support remote management. When the initial connection is established, the setup utility will run automatically, prompting you to perform the initial system configuration. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 64: Setting Up The Local Console

    Make sure the local terminal is configured as a VT-100 terminal, according to the fixed SCE 1000 CON port parameters. Step 4 Press Enter several times until the Cisco logo appears on the local terminal and the setup configuration dialog is entered. --- System Configuration Dialog --- At any point you may enter a question mark ‘?’...
  • Page 65: Initial System Configuration

    For further information regarding any configuration step or specific parameter, refer to the relevant Note section in the Cisco Service Control Engine (SCE) Software Configuration Guide. Setup Command Parameters Table 5-1 Setup Command Parameters...
  • Page 66 Community strings to allow GET access and associated ACLs (maximum 20). SET community names Community strings to allow SET access and associated ACLs (maximum 20). trap managers Trap manager IP address, community string, and SNMP version. (maximum 20) Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 67 Each group of related parameters is prefaced by a question, asking whether you want to enter the menu. To skip the menu, answer no (“n”) to the question. XAMPLE Would you like to enter the SNMP configuration menu? n Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 68: Step 1: Configuring Initial Settings

    Since the IP address and the subnet mask are related, when the IP address is changed, there is no longer a default value of the subnet mask, and it must be entered explicitly. Enter IP address [10.1.1.201]:10.1.5.109 Enter IP subnet mask:255.255.0.0 Enter IP address of default gateway [10.1.1.3]: Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 69: Step 2: Configuring The Hostname

    Note Passwords are needed for all authorization levels in order to prevent unauthorized users from accessing the SCE 1000. Admin level should be used by the network administrator. Root level is for use by Cisco technician. Passwords must meet the following criteria: Minimum length —...
  • Page 70: Step 4: Configuring Time Settings

    Unlike all other settings defined in the system configuration, setting the time is done immediately and Note not at the end of the setup process. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 71 You may enter an IP address for the SNTP unicast server. Type in the hostname or the IP address Step 8 in the form x.x.x.x, and press Enter Would you like to configure SNTP unicast servers? [no]: y Enter IP address or hostname of SNTP unicast server: 10.1.1.1 Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 72: Step 5: Configuring The Dns Settings

    You may accept the default domain name or enter a new one. Enter default domain name []: Step 4 Type the IP address of the primary domain name server and press Enter. Enter Primary DNS IP address: Cisco SCE 1000 2xGBE Installation and Configuration Guide 5-10 OL-7821-04...
  • Page 73: Step 6: Configuring The Rdr Formatter Destination

    Enter RDR-formatter destination’s TCP port number: XAMPLE Following is a sample RDR-formatter configuration dialog, assigning the IP address and TCP port number. Would you like to enter the RDR-formatter configuration menu? [no]: y Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 5-11...
  • Page 74: Step 7: Configuring Access Control Lists (Acls)

    Each individual IP address can be configured to be permitted or denied access. Table 5-2 IP address/Wildcard bit examples Initial IP address Wildcard bits Range 10.1.1.0 0.0.0.255 10.1.1.0–10.1.1.255 10.1.1.0 0.0.0.63 10.1.1.0–10.1.1.63 10.1.1.0 0.0.0.0 10.1.1.0 (individual entry) Cisco SCE 1000 2xGBE Installation and Configuration Guide 5-12 OL-7821-04...
  • Page 75: Order Of Entries

    Type “any” and press Enter to include any IP address in the ACL. Note that there is no default for this parameter. Enter IP address or the word ‘any’ to denote any IP address: Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 5-13...
  • Page 76 We therefore need to create two access control lists: For general IP access — permit access to all IP addresses. • For Telnet — permit access to the specified IP address, and deny to all others. • Cisco SCE 1000 2xGBE Installation and Configuration Guide 5-14 OL-7821-04...
  • Page 77: Step 8: Configuring Snmp

    Enter the SNMP configuration menu. Would you like to enter the SNMP configuration menu? [no]: y Type y and press Enter. The SNMP configuration dialog begins. Enable SNMP management. Step 2 Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 5-15...
  • Page 78 Would you like to add another SNMP SET community? [no]: Step 9 Enter the SNMP trap managers menu. Would you like to configure SNMP trap managers? [no]: y Type y and press Enter. The SNMP trap managers dialog begins. Cisco SCE 1000 2xGBE Installation and Configuration Guide 5-16 OL-7821-04...
  • Page 79 Enter SNMP SET community name[]: private Enter Access list number allowing access with this community string, use ‘0’ to allow all: 2 Would you like to add another SNMP SET community? [no]: Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 5-17...
  • Page 80: Step 9: Configuring The Topology-Dependent Parameters

    To define receive-only connection mode, type 2 and press Enter • Enter Connection mode: 1- inline 2- receive-only Enter your choice [1]: Step 3 Specify the On-failure link behavior. To specify Bypass, press Enter. • Cisco SCE 1000 2xGBE Installation and Configuration Guide 5-18 OL-7821-04...
  • Page 81 2- receive-only Enter your choice [1]: Enter On-failure behavior: 1- Bypass 2- Cutoff Enter your choice [1]: Enter admin status of the SCe after abnormal boot: 1- Operational 2- Not-Operational Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 5-19...
  • Page 82: Step 10: Completing And Saving The Configuration

    Found errors in the new configuration, would you like to view them? [yes]: The following errors were found: Warning - RDR formatter destination 10.1.1.1 is not allowed in the IP access-class. Cisco SCE 1000 2xGBE Installation and Configuration Guide 5-20 OL-7821-04...
  • Page 83 Would you like to view the new configuration before it is applied? [yes/no]: Found errors in the new configuration, would you like to view them? [yes]: y The following errors were found: Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 5-21...
  • Page 84 Would you like to view the new configuration before it is applied? [yes/no]: Apply and Save this configuration? [yes/no]: n The changes you have just entered would be discarded, are you sure? [yes/no]:y Setup procedure aborted, no configuration changes made. Cisco SCE 1000 2xGBE Installation and Configuration Guide 5-22 OL-7821-04...
  • Page 85: Connecting The Management Interface

    If the management port Link LED on the SCE 1000 still does not light, verify that the cable is connected correctly to the appropriate network element on its second end. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 5-23...
  • Page 86: Verifying Management Interface Connectivity

    64 bytes from host (10.1.1.201): icmp_seq=0. time=0. ms 64 bytes from host (10.1.1.201): icmp_seq=1. time=0. ms 64 bytes from host (10.1.1.201): icmp_seq=2. time=0. ms 64 bytes from host (10.1.1.201): icmp_seq=3. time=0. ms ----10.1.1.201 PING Statistics---- Cisco SCE 1000 2xGBE Installation and Configuration Guide 5-24 OL-7821-04...
  • Page 87 Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Connecting the Management Interface 4 packets transmitted, 4 packets received, 0% packet loss round-trip (ms) min/avg/max = 0/0/0 Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 5-25...
  • Page 89: Cabling The Line Ports And Completing The Installation

    Before beginning, find the appropriate cabling diagram for the topology in your installation: Single SCE 1000 topologies • • Single Link: Inline Topology (on page 6-2) Single Link: Receive-only Topology (on page 6-2) • Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 90 1000. The SCE 1000, therefore, is in receive-only topology, having only traffic monitoring capabilities. Receive-only topologies can also be implemented using a switch. Such a switch must support SPAN Note functionality that includes separation between ingress and egress traffic and multiple SPAN-ports destinations. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 91: Configuring The Gbe Interface Parameters

    In order to prevent errors when in bypass mode, the system must be configured so that the speed and Note duplex of both line interfaces is the same. If you change any parameters, you must save the new configuration settings. Note Type copy running-config startup-config, and press Enter. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 92 To exit Global Configuration Mode, type exit and press Enter. Step 4 The SCE 1000# prompt appears. Auto-negotiation must be disabled when the SCE 1000 is deployed via an external optical splitter (i.e. Note receive-only topology). Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 93: Connecting The Gbe Line Interface Ports

    When installing an External Optical Bypass module, the SCE 1000 line ports are connected to the Note module. See Cabling the External Optical Bypass Module (on page A-4) for complete instructions. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 94: Fiber Specifications

    Figure 6-3: Cabling the <ETH> Interface Step 2 Verify that the link LED is green. If the link LED does not light, try removing the network cable plug and reinserting it firmly into the module socket. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 95: Testing Connectivity: Examining Link Leds And Counters

    Again, auto-negotiation for bump-in-the-wire topology may be enabled or disabled. For receive- only topologies, using an external splitter, auto-negotiation must be disabled. To view the Gigabit Ethernet counters: Step 1 Type show interface Gigabit Ethernet 0/interface counters Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 96: Loading And Activating A Service Control Application

    The detailed procedure of how to perform these operations is not specified and described in this manual. For further details, refer to the following documentation: Service Control Application Suite for Broadband User Guide • Service Control Application Suite for Broadband Reference Guide • Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 97: Basic Sce 1000 Platform Operations

    SCE 1000 platform is connected to at least one of the following types of management • stations: Direct connection to local console (CON port) • Remote management station via the LAN (Mng port) • Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 98: Starting The System And Observing Initial Conditions

    Step 5 a script and system banner similar to the following: Cisco Internetwork Operating System Software IOS (tm) 7300 Software (C7300-JS-M), Version 12.1(9), CISCO RELEASED VERSION Copyright (c) 1986-2001 by Cisco Systems, Inc. Compiled Tue 17-Jul-01 01:51 by biff Image text-base:0x40008970, data-base:0x40BF8000...
  • Page 99: Final Tests

    Total error messages: 0 Total fatal messages: 0 If there are “Total error messages” or “Total fatal messages”, use the show logger device User-File-Log command to display details about the errors. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 100: Managing Sce 1000 Configurations

    UDP 60 interface FastEthernet 0/0 ip address 10.1.5.109 255.255.0.0 interface FastEthernet 0/1 interface FastEthernet 0/2 exit line vty 0 4 no timeout exit SCE 1000# Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 101 Logger status: Enabled Platform: SCE 2000 - 4xFE Management agent interface version: SCE Agent 2.5.1 Build 18 Software package file: ftp://vk:vk@10.1.8.22/P:/EMB/LatestVersion/2.5.2/se1000.pkg SCE 2000 uptime is 21 minutes, 37 seconds SCE 1000# Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 102: Saving The Configuration Settings

    The configuration file holds all information that is different from the system default in a file called config.txt located in the directory: tffs0:system. XAMPLE The following example shows the running configuration file. SCE 1000#show running-config #This is a general configuration file (running-config). Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 103 To remove a configuration command from the running-config, use the no form of the command. XAMPLE The following example illustrates how to remove all DNS settings from the running configuration. SCE 1000(config)#no ip name-server SCE 1000(config)# Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 104: Recovering A Previous Configuration

    LineCard 0 no silent no shutdown interface FastEthernet 0/0 ip address 10.1.5.109 255.255.0.0 interface FastEthernet 0/1 interface FastEthernet 0/2 exit line vty 0 4 exit SCE 1000#copy tffs0:system/prevconf/config.tx1 tffs0:system/config.txt SCE 1000# Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 105: Performing Complex Configurations

    For further information on system and interface configuration, refer to the following documents: Cisco Service Control Engine (SCE) Software Configuration Guide • •...
  • Page 106: Shutting Down The Sce Platform

    (or cycling the power), this command can only be executed from the serial CLI console. This limitation helps prevent situations in which a user issues this command from a Telnet session, and then realizes he/she has no physical access to the SCE 1000 platform. Cisco SCE 1000 2xGBE Installation and Configuration Guide 7-10 OL-7821-04...
  • Page 107: Troubleshooting

    Make sure to review the safety warnings listed in the Regulatory Compliance and Safety Information for the Cisco Service Control Engine document that accompanied your SCE 1000 platform before using the troubleshooting procedures in this chapter.
  • Page 108: Troubleshooting Tools

    There are three tools that will help you to successfully troubleshoot your SCE 1000 installation: CLI Commands for Troubleshooting (on page 8-3) • • The User Log (on page 8-4) Check the LEDs (on page 8-7) • Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 109: Cli Commands For Troubleshooting

    Use the following commands to provide information to help you troubleshoot installation of your SCE 1000 platform. Refer to Cisco Service Control Engine (SCE) Software Configuration Guide or the Cisco Service Control Engine (SCE) CLI Command Reference for more information.
  • Page 110: The User Log

    Basic operations include: Copying the User Log to an external source • Viewing the User Log • Clearing the User Log • Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 111: Copying The User Log

    Copying the User Log (on page 8-5)) To view the user log: From the SCE 1000# prompt, type more user-log and press Enter. The user log appears, followed by the SCE 1000# prompt. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 112: Clearing The User Log

    To view the non-volatile counter for the user-file-log only, use the following command: From the SCE 1000# prompt, type show logger device user-file-log nv- counters and press Enter. The user-file-log non-volatile log counter information appears, followed by the SCE 1000# Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 113: Check The Leds

    In order for technical support to be most effective, the user should provide them with the information contained in the system logs. Use the logger get support-file command to generate a support file for the use of Cisco technical support staff. To generate a log file for technical support: From the SCE 1000# prompt, type logger get support-file filename and press Enter.
  • Page 114: Problem Solving Using A Subsystems Approach

    When you start up the system by turning on the power supply switch, the following should occur: You should immediately hear the fans operating. • Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 115: Troubleshooting The Power Subsystem

    Turn the switch to the off position, connect the power cable to another power source, if available, and turn the switch back on. Faulty power cable. Turn the switch to the off position, remove the cable and replace it. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 116 Green Steady Corresponding power supply unit is present and functioning normally. Steady Corresponding power supply unit present, but malfunctioning. Corresponding power supply unit is either not present or has failed. Cisco SCE 1000 2xGBE Installation and Configuration Guide 8-10 OL-7821-04...
  • Page 117: Troubleshooting The Firmware Package Installation

    Error—There are only again. X free bytes on device <device name>, but Y bytes are needed for the extraction (where X and Y are stated in bytes) Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 8-11...
  • Page 118: Troubleshooting The Management Subsystem

    • IP address / subnet mask Cisco Service Control Engine (SCE) is lit gateway Software Configuration Guide. • ping to • IP default gateway management interface fails Cisco SCE 1000 2xGBE Installation and Configuration Guide 8-12 OL-7821-04...
  • Page 119: Show Line Vty

    Initial System Configuration page 5-3) lists • show line vty Refer to "Access Control Lists" in the Cisco Service Control Engine access-class (SCE) Software Configuration Guide. • show ip access- class Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 8-13...
  • Page 120: Troubleshooting The Link Interface Subsystem

    • Output counters not incrementing. GBE cable is broken Reconnect / replace the cable to the GBE port. If GBE counters are incrementing, this indicates LED problem. Contact customer support. Cisco SCE 1000 2xGBE Installation and Configuration Guide 8-14 OL-7821-04...
  • Page 121 Auto-negotiation is disabled at Check auto-negotiation the SCE 1000 but enabled at ("Configuring the GBE peer Interface Parameters" on page 6-3) configuration in the SCE 1000 and in peer. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 8-15...
  • Page 123: The External Optical Bypass Module

    An External Optical Bypass module enables the implementation of such replacement while preserving normal operation of the network link. The External Optical Bypass module is another important component in the Cisco overall carrier- grade solution for high-availability service provider networks.
  • Page 124: External Optical Bypass Functionality

    Note that when the bypass module is active, it puts the SCE 1000 platform into a loop connection, creating a shortcut between the SCE 1000 platform GBE interfaces. Figure A-2: External Optical Bypass Module: Active (in bypass) Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 125: The External Optical Bypass Module Front Panel

    Installation of the External Optical Bypass module requires two main steps, which are described in detail in the following sections. To install the External Optical Bypass module: Install the module in the rack. Step 1 Cable the module. Step 2 Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 126: Installing The Module In A Rack

    Connect the control cable to the Bypass 9-pin D-Type connector on the rear of the SCE 1000 • platform. Figure A-4: Bypass Connector on the Rear of the SCE 1000 Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 127 Verify that the relevant GBE interfaces of the SCE 1000 platform are now in sync, as the External Optical Bypass module is now active (in bypass), and is performing a loop back on these interfaces. Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 128: Specifications

    12 oz (340 g) Table A-1 Control cable pinouts Function Pin (D-type side) Pin (RJ-45 side) Bypass Present (common to 2) Bypass Present (common to 1) 7-NC 8-NC 9-NC Shield Shield Shield Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 129: Index

    Fan Module Overview • 4-20 Collection • 1-6 Fiber Specifications • 6-6 Configure GigabitEthernet Auto-Negotiation Final Tests • 7-3 • 6-5 Front Panel • 2-2 Configuring Auto-Negotiation • 6-3 Functionality • 3-3 Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 130 Physical Installation • 3-3, 3-6 Setup Command Parameters • 5-3 Power Supply Overview • 4-11 Shutting Down the SCE Platform • 7-10 Power Supply Specifications • 4-14 Single Link Inline Topology • 6-2 Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04...
  • Page 131 Panel • A-3 The Logging System • 8-4 The SCE Platform • 1-3, 2-1 The User Log • 8-4 Tools and Parts Required • 4-2 Topology • 3-1 Topology-Related Parameters • 3-7 Cisco SCE 1000 2xGBE Installation and Configuration Guide OL-7821-04 I-33...

This manual is also suitable for:

Sce 1000 2xgbe

Table of Contents