27.4 Recommended Operating Conditions
27.4.1 Recommended operating conditions (µPD70F3402)
Operation
Mode
Normal Mode
27.4.2 Recommended operating conditions (µPD70F3403, µPD70F3403A)
Operation
Mode
Normal Mode
Downloaded from
Elcodis.com
electronic components distributor
Chapter 27 Electrical Specification
Operating Ambient
International Operating
Temperature (T
Clock Frequency
24 MHz, 32 MHz
REGC1: Capacity=4.7 µF
REGC0: Capacity=1.0 µF
Operating Ambient
International Operating
Clock Frequency
24 MHz, 32 MHz, 40 MHz
REGC1: Capacity=4.7 µF
REGC0: Capacity=1.0 µF
User's Manual U16702EE3V2UD00
Digital Power
Supply (V
)
A
V
, BV
DD1
-40°C to +110°C
4.0 V – 5.5 V
Digital Power
Supply (V
Temperature (T
)
A
V
DD1
-40°C to +85°C
4.0 V – 5.5 V
Analog Power
,
DD0
Supply (AV
)
REF0
)
DD
4.5 V – 5.5 V
Analog Power
,
DD0
Supply (AV
)
REF0
, BV
)
DD
4.5 V – 5.5 V