Table 16-4: Frame Format Setting (Ide Bit) And Number Of Identifier (Id) Bits; Table 16-5: Data Length Setting - NEC V850E/RS1 User Manual

32-/16-bit single-chip microcontroller with can interface
Table of Contents

Advertisement

<3> Control field
The control field sets "N" as the number of data bytes in the data field (N = 0 to 8).
Remark:
In a standard format frame, the control field's IDE bit is the same as the r1 bit.
Caution:
532
Downloaded from
Elcodis.com
electronic components distributor
Chapter 16 FCAN Controller

Table 16-4: Frame Format Setting (IDE Bit) and Number of Identifier (ID) Bits

Frame Format
Standard format mode
Extended format mode
Figure 16-8: Control Field
(Arbitration field)
R
D
RTR
r1
(IDE)
D: Dominant = 0
R: Recessive = 1

Table 16-5: Data Length Setting

Data Length Code
DLC3
DLC2
DLC1
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
1
0
Other than above
In the remote frame, there is no data field even if the data length code is not 0000B.
User's Manual U16702EE3V2UD00
SRR Bit
IDE Bit
None
0 (D)
1 (R)
1 (R)
Control field
r0
DLC3
DLC2
DLC1
Data Byte Count
DLC0
0
0
0 bytes
0
1
1 byte
1
0
2 bytes
1
1
3 bytes
0
0
4 bytes
0
1
5 bytes
1
0
6 bytes
1
1
7 bytes
0
0
8 bytes
8 bytes regardless of the value of
DLC3 to DLC0
Number of Bits
11 bits
29 bits
(Data field)
DLC0

Advertisement

Table of Contents
loading

Table of Contents